See
on page 158 for more information.
Stacking
Each X465 unit comes equipped with two 40GbE stacking ports using a QSFP interface, located on the
front panel of the switch. Standard 40 Gb Ethernet Optics and passive and active cables can be used in
the QSFP ports for stacking X465s together using SummitStack-V160.
Stacking cables for X465 switches are ordered separately. For a list of X465 ports that can be used with
SummitStack-V160, see
ExtremeSwitching X465 Stacking
on page 201.
For information about QSFP and QSFP+ optical modules, see the
Transceivers Installation Guide
.
Operating Temperatures
All X465 switch models support an operating range from 0°C to 50°C. Temperature restrictions apply
for some models at high altitudes.
ExtremeSwitching X465-24MU Switch Ports and Slots
The front panel of the ExtremeSwitching X465-24MU switch includes:
•
24 100Mb/1/2.5/5Gb ports with 802.3bt Type 3 PoE (60W)
•
1 VIM5 slot
•
Stacking ports
•
2 USB A ports
•
1 USB micro B management port
The rear panel of the ExtremeSwitching X465-24MU switch includes:
•
2 fan modules
•
2 unpopulated PSU slots
•
RJ-45 console and management ports
•
1 SSD port
Solid-state Drives (SSDs)
SSD module support is available with EXOS release 30.3 and later for X465-24MU.
ExtremeSwitching Switches
Stacking
ExtremeSwitching Hardware Installation Guide
77