62
ExtremeSwitching SLX 9140 Hardware Installation Guide
9036857-00 Rev AA
LEDs
LEDs
Other
Weight and physical dimensions
Environmental requirements
System component
Description
Device status and
management
Two LED types indicate device status:
Power (power supply)
Status (diagnostics)
Ports
LEDs indicate port status (link/activity)
System component
Description
Serial cable
1 (Mini-USB to RJ-45)
RJ-45 to DB9 adapter
1 (RJ-45 port to female DB9 connector)
AC power cord
IEC 320-C14
Height
Width
Depth
Fully loaded weight
(no transceivers)
4.37 cm
1.72 inches
44.0 cm
17.32 inches
44.47 cm
17.51 inches
8.99 kg
19.82 lb
Condition
Operational
Non-operational
Ambient temperature
*
*.
Worst case operational temperature is measured at sea level with at least 4 fan assemblies, with maximum power consumption optics modules (5W
QSFP28/2W SFP28) fully loaded.
-5°C to 50°C (23°F to 122°F) (F2B)
-5°C to 45°C (23°F to 113°F) (B2F), temporarily to 55°C with 6 fan
assemblies
-40°C to 70°C (-40°F to 158°F)
Relative humidity
5% to 95% at 50°C (122°F)
5% to 95% at 70°C (158°F)
Altitude
0 to 3,000 m (9,843 ft) safety
-60 to 4,000 m (13,123 ft) operational
0 to 12,000 m (39,370 ft)
Shock
20 G, 11 ms, half-sine wave
33 G, 11 ms, half-sine wave
Vibration
1 G sine, 0.4 grms random, 5-500 Hz
2.4 G sine, 1.1 grms random, 5-500 Hz
Airflow
134 cfm (estimated with 2 power supplies, 5 fan assemblies)
N/A
Heat dissipation
(worst case)
DC power supply 475 W
AC power supply 489 W
N/A
Operating noise
52.6 dBA (5 fan assemblies, 25°C, typical loading)
N/A
MTBF (25°C, 60% CL, Telec)
303,683 hours with DC power supply
324,414 hours with AC power supply
N/A
Содержание ExtremeSwitching SLX 9140
Страница 6: ...vi ExtremeSwitching SLX 9140 Hardware Installation Guide 9036857 00 Rev AA ...
Страница 10: ...x ExtremeSwitching SLX 9140 Hardware Installation Guide 9036857 00 Rev AA Contacting Extreme Technical Support ...
Страница 12: ...2 ExtremeSwitching SLX 9140 Hardware Installation Guide 9036857 00 Rev AA Supported hardware and software ...
Страница 54: ...44 ExtremeSwitching SLX 9140 Hardware Installation Guide 9036857 00 Rev AA Connecting network devices ...
Страница 76: ...66 ExtremeSwitching SLX 9140 Hardware Installation Guide 9036857 00 Rev AA Regulatory compliance environmental ...