17
ExtremeSwitching SLX 9140 Hardware Installation Guide
9036857-00 Rev AA
Installing the Universal Two-Post Rack Kit (XBR-R000294)
Parts list
The following parts are provided with the Universal Two-Post Rack Kit (XBR-R000294).
FIGURE 7
Rack kit parts
Ensure that the items listed and illustrated in
are included in the kit. Note that not all parts may be used with certain installations
depending on the device type.
Flush-front mounting
Complete the following tasks to install the device in a two-post rack.
1.
“Attaching the front brackets”
2.
“Attaching the front brackets to the rack posts”
3.
“Attaching the rear brackets to the rack posts”
1
Front brackets (2)
5
Screw, 8-32 x 5/16-in., flathead Phillips (16)
2
Rear brackets, 5-6 inch post (2)
6
Screw, 6-32 x 1/4-in., panhead Phillips (8)
3
Rear brackets, 3-5 inch post (2)
7
Screw, 10-32 x 5/8-in., panhead Phillips (8)
4
Screw, 8-32 x 5/16-in., panhead Phillips (8)
8
Retainer nut, 10-32 (8)
CAUTION
Use the screws specified in the procedure. Using longer screws can damage the device.
CAUTION
The device must be turned off and disconnected from the fabric during this procedure.
Содержание ExtremeSwitching SLX 9140
Страница 6: ...vi ExtremeSwitching SLX 9140 Hardware Installation Guide 9036857 00 Rev AA ...
Страница 10: ...x ExtremeSwitching SLX 9140 Hardware Installation Guide 9036857 00 Rev AA Contacting Extreme Technical Support ...
Страница 12: ...2 ExtremeSwitching SLX 9140 Hardware Installation Guide 9036857 00 Rev AA Supported hardware and software ...
Страница 54: ...44 ExtremeSwitching SLX 9140 Hardware Installation Guide 9036857 00 Rev AA Connecting network devices ...
Страница 76: ...66 ExtremeSwitching SLX 9140 Hardware Installation Guide 9036857 00 Rev AA Regulatory compliance environmental ...