Safety Instructions
When a connector is removed during installation, testing, or servicing, or when an energized fiber is
broken, a risk of ocular exposure to optical energy that may be potentially hazardous occurs, depending
on the laser output power.
The primary hazards of exposure to laser radiation from an optical-fiber communication system are:
•
Damage to the eye by accidental exposure to a beam emitted by a laser source.
•
Damage to the eye from viewing a connector attached to a broken fiber or an energized fiber.
Technical Specifications
Model
ISW
Ethernet
Copper RJ45 Ports
10/100/1000 Mbps speed auto-negotiation MDI/MDIX Auto-crossover
SFP (pluggable Ports)
100/1000Base SFP slot
Fiber port connector
LC typically for fiber (depends on module)
Power
Power input
Redundant Input Terminals; Reverse power protection
Input voltage range
12-58 VDC (with POE: 46-58 VDC)
Maximum Power
consumption
: 14 Watts
With PoE: 265 Watts
Environmental and Compliances
Operating temperature
-40 to +75°C (cold startup at -40°C)
Storage temperature
-40 to +85°C
Humidity
5 to 95% RH (non-condensing)
Mechanical
Ingress protection
IP30
Dimension
(without DIN rail clip)
154mm(H) x 128mm(D) x 77mm(W)
Weight
1410g