2020 ExtraHop Networks, Inc. All rights reserved.
Deploy the ExtraHop Trace 6150 Appliance
Published: 2020-02-21
This guide explains how to install the rack-mounted ETA 6150 ExtraHop Trace appliances.
System requirements
This guide explains how to install the rack-mounted ETA 6150 ExtraHop Trace appliance.
Appliance
2U of rack space
2x750W of power
Network Access
TCP ports 80 and 443 must be open.
These ports enable you to administer the Trace appliance through the ExtraHop Web UI. Requests sent
to port 80 are automatically redirected to HTTPS port 443.
Rear panel ports
•
One iDRAC interface port
•
One RS-232 serial port to connect a console device
•
One VGA port to connect an external display
•
Two USB 3.0 ports to connect input devices such as a keyboard and mouse
•
Two 10/100/1000 BASE-T network ports. Port 3 is the primary management port.
•
Four 10 GbE ports. Ports 5 and 6 are the monitoring (capture) interfaces.
•
Two power ports to connect the appliance to an AC power source
Set up the appliance
1. Rack mount the Trace appliance.
Install the Trace appliance in your data center with the included rack-mounting kit. The mounting kit
supports most four-post racks with either round or square holes.
2. Connect port 3.
Connect your management network to the 1 GbE interface on port 3.
3. Connect the 10 GbE port.