Deploy the ExtraHop Trace 6150 Appliance

Published: 2020-02-21

This guide explains how to install the rack-mounted ETA 6150 ExtraHop Trace appliances.

System requirements

This guide explains how to install the rack-mounted ETA 6150 ExtraHop Trace appliance.

Appliance

2U of rack space

2x750W of power

Network Access

TCP ports 80 and 443 must be open.
These ports enable you to administer the Trace appliance through the ExtraHop Web UI. Requests sent

to port 80 are automatically redirected to HTTPS port 443.

Rear panel ports

One iDRAC interface port

One RS-232 serial port to connect a console device

One VGA port to connect an external display

Two USB 3.0 ports to connect input devices such as a keyboard and mouse

Two 10/100/1000 BASE-T network ports. Port 3 is the primary management port.

Four 10 GbE ports. Ports 5 and 6 are the monitoring (capture) interfaces.

Two power ports to connect the appliance to an AC power source

Set up the appliance

1. Rack mount the Trace appliance.

Install the Trace appliance in your data center with the included rack-mounting kit. The mounting kit

supports most four-post racks with either round or square holes.

2. Connect port 3.

Connect your management network to the 1 GbE interface on port 3.

3. Connect the 10 GbE port.