oPeratIon and loGIC
IGnItIon
Once the previously listed points have been checked, press key 1 for three seconds to ignite the stove. During ignition, the stove will check
for a flame for a period of 15 minutes. Once the control temperature has been reached, the stove interrupts the ignition phase and switches
to PreParatiON.
the stove is set to maNuaL mode, power 5, by default.
PreParatIon
During the preparation phase, the stove stabilises combustion, increasing it progressively, to then start ventilation and switch to wOrK
work In
maNuaL mODe
During the work phase, the stove reaches the POwer defined by the user, heating the room using the VeNtiLatiON set by the user.
adjustment In set temPerature
mODe
this mode, by means of the set tHermOstat, allows for the room temperature to be set.
the adjustment is made using buttons 2 and 3, from 7 to 37°C.
the stove controls the room temperature using a probe built into the radio control.
see paragraph mODe for more details.
auX mode
if aux mODe is selected, temperature control is entrusted to the contact of the additional thermostat, thus ignoring the temperature probe
built into the radio control.
if the contact is open (met), the stove operates at the minimum value (or it switches off if staND BY mode is active).
if the contact is closed (request), the stove works at the set power.
reGulatIon oF set Power
set Power has 5 levels of operation. the power can be changed with keys 2 or 3.
Power 1 = minimum level - Power 5 = maximum level.
Press key 1 to exit and save the change.
auto Blow
During the work phase, the stove cleans the burn pot at regular intervals with the function called "autO BLOw".
when this procedure starts, a message is displayed. During the "autO BLOw" procedure, the pellet feed slows down and the fumes motor
increases.
after cleaning, the stove resumes operation in normal conditions.
swItCH-oFF
Press key 1 for three seconds.
Once this operation has been performed, the appliance automatically enters the switch-off phase, blocking the pellet feed.
the flue gas exhaust motor and the hot air flow motor will remain on until the stove temperature has dropped below the safety settings.
reIGnItIon
the stove can only be re-ignited if the temperature of the exhaust fumes is lower than the preset threshold and the minimum safety time has
passed.
It Is ForBIdden to use tHe devICe wItHout tHe Flame Guard (see
FIGure to tHe sIde). removal wIll ComPromIse tHe saFety oF tHe
ProduCt and result In tHe ImmedIate nullIFICatIon oF tHe warranty
PerIod. In tHe event oF wear or deterIoratIon, ask tHe aFter-sales
servICe to rePlaCe tHe Parts (rePlaCement does not Fall wItHIn tHe
ProduCt warranty as tHe Part Is suBjeCt to wear).
FLame guarD