OFF
ENGLISH
Control panel
BUTTON
ON/OFF
Display OF variOUs
TexT messages
TO aCCess
THe meNU
TemperaTUre
seTTiNg
OperaTiON pOWer
aDJUsTmeNT
Display iCons key
indicates the receipt of the radio signal
On = during radio communication
Off = no radio communication
Flashing = serial port excluded
indicates the stove modulation
On = the stove is working at the set power
Flashing = the power at which the stove is working is different to the power
set, the stove is modulating (for various reasons)
indicates the presence of an alarm.
On: indicates the presence of an alarm
Off: indicates the absence of alarms
Flashing: indicates the deactivation of the depression sensor.
it indicates weekly programming functioning
indicator on = weekly programming active
indicator off = weekly programming disabled
indicates the water temperature status
Off = the T° read by the probe is over the set temperature set
On = the T° read by the probe is below the set temperature set
indicates the contact of the external additional thermostat
Closed contact = the contact of the external additional thermostat is closed.
Open contact: the contact of the external additional thermostat is open.
Flashing with contact closed: the contact of the external additional thermo-
stat is closed and the sTBy function is activated
Flashing with contact open: the contact of the external additional thermostat
is open and the sTBy function is activated
it indicates functioning of the fumes motor.
Off = flue gas motor deactivated
On = flue gas motor active
Flashing = breakdown (contact technical after-sales service)
it indicates the summer/winter function (with an additional board)
Off: activates the winter function
On: activates the summer function
Not used
it indicates the boiler request (with an additional board)
Off = DHW satisfied, pump off
Flashing : the puffer request exists but the work conditions are not satisfied,
pump off
On : the puffer is in request mode and the work conditions are satisfied,
pump on
it indicates functioning of the pellet feed motor
Off = pellet feed motor deactivated
On = pellet feed motor active
it indicates the heating request (with an additional board)
Off : heating satisfied, pump off
Flashing : the heating request exists but the work conditions are not satisfied,
pump off
On : the heating is in request mode and the work conditions are satisfied,
pump on
it indicates pump operation
Off = pump deactivated
On = pump active
Flashing = the safety device is active (H2O temperature > 85°C)
it indicates the puffer request (with an additional board)
Off : puffer satisfied, pump off
Flashing : the puffer request exists but the work conditions are not satisfied,
pump off
On : the puffer is in request mode and the work conditions are satisfied,
pump on
21