Extraflame COMFORT P70 AIR Скачать руководство пользователя страница 22

22

ENGLISH

BATTERY TYPE AND REPLACEMENT

To  insert/replace  the  batteries,  su

ffi

ce  it  to  remove  the  battery 

protection cover at the back of the radio control device (

fi

gure 1).

Insert the batteries in accordance with the symbols imprinted on 

the radio control device and on the battery itself. 

Three  AAA  batteries  are  required  for  the  radio  control  to 

function.

CONFIGURATION

RADIO CONTROL CODING PROCEDURE:

1.  Disconnect the power supply to the stove.
2.  Press the keys 

 

OK

 and

 

OK

at the same time until the screen to choose 

RADIO ID

 appears.

3.  Using keys 

 

OK

 and 

 

OK

 select the new 

RADIO ID

.

4.  Power the stove. Con

fi

rm the selected unit within 10 seconds (the LED will 

fl

ash on the radio/emergency card) by pressing the OK key 

on the remote control.
5.  The LED on the radio/emergency card will remain on for 5 seconds to con

fi

rm the new con

fi

guration.

6.  If the con

fi

guration was unsuccessful, the display will read "

". In this case, repeat the procedure.

J

THE  RADIO  CONTROL  IS  ALREADY  CONFIGURED  WITH  "RADIO  ID"  0".  IF  THERE  IS  ANOTHER  STOVE,  TO  AVOID 
INTERFERENCES, A NEW CONFIGURATION MUST BE PERFORMED, MODIFYING ONE OF THE TWO STOVES.

SOME RADIO FREQUENCY DEVICES 

(

E.G. MOBILE PHONES, ETC.

)

 MAY CAUSE INTERFERENCE WITH 

COMMUNICATION BETWEEN THE RADIO CONTROL AND THE STOVE.

Respect the environment!

Used batteries contain metals that are harmful to the environment, and therefore must be disposed of separately in 

special containers.

RADIO CONTROL

(

fi

gure 1)

RADIO CONTROL ROOM PROBE 

CALIBRATION

This mode allows calibration of the room temperature detected 

by  the  radio  control  (with  ventilation  active  only).  For  correct 

calibration, it is recommended to position the radio control in a 

room with constant temperature and wait for at least two hours.

The procedure for calibration is the following:

 

Š

Access the menu and reach “

TECH MENU

”.

 

Š

Set the access key "F4". - "

ADJ REMOTE PROBE

"

 

Š

Using the keys 

 

OK

  or 

 

OK

  adjust the desired ambient 

calibration.

 

Š

Save and exit with the key 

 

OK

 .

Содержание COMFORT P70 AIR

Страница 1: ...MADE IN ITALY design production INSERTO COMFORT P70 AIR P70 AIR PLUS 004280424 Rev 000 UK PELLET STOVES USER MANUAL...

Страница 2: ...2 ENGLISH APPLY TECHNICAL DATA LABEL...

Страница 3: ...AL MENU 25 GENERAL WARNINGS 25 FIRST IGNITION SETTINGS 26 DATE TIME 26 LANGUAGE 26 DEGREES 26 OPERATION AND LOGIC 27 MODES 28 FRONT AIR 28 AIR DUCTING P70 AIR PLUS ONLY 28 AIR ZONE CONTROL P70 AIR PLU...

Страница 4: ...ance has been installed as well as the instructions contained in this manual The use of the appliance must comply with all local regional national and European regulations The Manufacturer cannot be h...

Страница 5: ...IF IT IS DISCONNECTED FROMTHE MAINS IT IS ADVISED TO POSITION THE POWER SUPPLY CABLE SO THAT IT DOES NOT COME INTO CONTACT WITH HOT PARTS OFTHE APPLIANCE THE POWER SUPPLY PLUG MUST BE ACCESSIBLE AFTE...

Страница 6: ...CLEAN THE MAJOLICAS IT IS RECOMMENDED TO USE A SOFT DRY CLOTH IF A DETERGENT OR LIQUID IS USED THE LATTER COULD PENETRATE INSIDE THE CRACKLES HIGHLIGHTING THEM SINCE THE PRODUCT CAN TURN ON AUTOMATICA...

Страница 7: ...mestichotwaterproductionandinadjacentandcommunicating rooms 3 where the depression measured in situ between the external and internal environment is greater than 4 Pa N B Watertight appliances can als...

Страница 8: ...lways be insulated The smoke ducts must have at least one airtight inlet for flue gas sampling All the sections of the flue gas duct must be accessible to inspection Inspection openings must be provid...

Страница 9: ...S OF INSERTO COMFORT P70 AIR A Ambient air outlet E Pellet hopper I TA inlet B Access to combustion chamber and ash drawer F Fuse J 230V power supply C Emergency module G Rail K Combustion air inlet D...

Страница 10: ...S A Room air outlet E Pellet hopper J 230V power supply B Access to combustion chamber and ash drawer F Air ducting Z1 outlet K Combustion air inlet C Emergency module G H Fuse Bulb thermostat reactiv...

Страница 11: ...or cleaning at the end of the season If there is no pre existing chimney one can be built using an insert holder pedestal optional kit In fact the latter fixes the insert to the ground ASSEMBLY place...

Страница 12: ...oor and release the latch using the poker supplied Remove the 6 screws and remove the flue pipe from the base Fix the base to the existing flue pipe ATTENTION RESPECT THE 50MM HEIGHT FOR OPENING AND C...

Страница 13: ...NGLISH Fix the base to the kit if it is a new installation optional kit Block the rails with two screwdrivers and secure the flue pipe to the base with 6 screws Close the insert and block the latch 3b...

Страница 14: ...ITH TOTAL MINIMUM SURFACE 240 CM UPPER PART HOT AIR OUTLET WITH TOTAL MINIMUM SURFACE 240 CM The possible set ups which must be respected are indicated below EXISTING INSTALLATION FOR INSTALLATION ON...

Страница 15: ...must be guaranteed the coatings must be made of non flammable material IMPORTANT ALL THE OPENINGS CREATED FOR THE CORRECT AIR CIRCULATION MUST PREVENT THE ENTRY OF HAZARDOUS PARTS BY USING SPECIFIC GR...

Страница 16: ...wise to block Holes present on two sides for the extraction of the insert via pokers Extraction of the insert allows both the pellets to be loaded inside the hopper and routine maintenance cleaning th...

Страница 17: ...to very high pressures This type of fuel is fully ecological as no glues are used to hold it together Indeed the pellets remain compact over time due to a natural substance found in wood lignin As we...

Страница 18: ...earms should be triggered so as to verify the cause FUSE If the stove is not powered it is recommended to have the fuse checked by a qualified technician OPTIONAL LOADING ACCESSORIES FRONT PELLET LOAD...

Страница 19: ...the temperature has been reached contact open the motor will switch to minimum The duct thermostat terminal features a standard bridge See the example image COMFORT P70 AIR PLUS HOT AIR DUCTING The mo...

Страница 20: ...ture from 7 to 37 C Oncethespecificactivationthresholdhasbeenreachedandexceeded attemperature to be satisfied the air ducting motor will follow the stove settings When the set TEMPERATURE is reached t...

Страница 21: ...he basic operation of the stove in the event the handheld remote is damaged or malfunctions The functions that can be managed from the emergency module are Key P1 Stove ignition switch off L1 Blue LED...

Страница 22: ...uccessful the display will read In this case repeat the procedure J THE RADIO CONTROL IS ALREADY CONFIGURED WITH RADIO ID 0 IF THERE IS ANOTHER STOVE TO AVOID INTERFERENCES A NEW CONFIGURATION MUST BE...

Страница 23: ...ent The radio control is fitted with an LCD backlit display The display remains lit for 5 seconds After a certain period of time in order to minimise battery consumption the display turns off sleep mo...

Страница 24: ...TA DISPLAY Display text Temperature detected in room Set ambient temperature Power 1 5 Hour Chrono active STAND BY active Battery low display text Time Indicates contact of the external additional th...

Страница 25: ...the product it is necessary to perform the following checks If it is intended to be connected to a hydraulic system it must be complete and fully functional and in compliance with the instructions giv...

Страница 26: ...to set the desired unit of measurement To set OK SETTINGS DEGREES FIRST IGNITION SETTINGS After connecting the power cord at the back of the generator turn the switch if any to position I The switch...

Страница 27: ...radio control temperature probe If the contact is open fulfilled the stove works at minimum power If the contact is closed request the stove works at the set power If the setting is on HOT set above 3...

Страница 28: ...O ARE INSUFFICIENT N B IF THESE ADJUSTMENTS DO NOT SOLVE THE PROBLEM OF PELLET DEPOSITS IN THE BURN POT PLEASE CONTACT YOUR LOCAL SERVICE CENTRE AIR DUCTING P70 AIR PLUS ONLY This menu allows you to s...

Страница 29: ...esired power Current day and time settings are essential for the correct operation of the Chrono To set OK CHRONO PRGX ENABLING Allows the chrono and the different stove time slots to be enabled disab...

Страница 30: ...00 23 00 08 00 16 30 t 22 18 2 1 30 ENGLISH Time slot 1 start 02 00 stop 23 00 Set Power 3 Set Temp 22 C Time slot 2 start 08 00 stop 16 30 Set Power 1 Set Temp 18 C stove operation Time slot Set Pow...

Страница 31: ...RMOSTAT OPTIONAL STAND BY FUNCTION SET TO OFF FACTORY SETTING When the STAND BY function is not activated OFF if the stove exceeds the room temperature set on the supplementary thermostat open contact...

Страница 32: ...ery life by 30 The battery life depends on the usage To set OK SETTINGS DEPRESSURE NOTICE DELAY SWITCH OFF Youcanprogramadelayedswitch offforthestove Forexample ifitis8pmandthedelayedswitch offissetto...

Страница 33: ...anty CLEANING THE CERAMIC GLASS Never use abrasive or chemically aggressive detergents for cleaning The ceramic glass must be cleaned when the glass is completely cold To clean the ceramic glass simpl...

Страница 34: ...Suck up the ash from the burn pot seat and combustion chamber Re position the burn pot in its slot and push it towards the fire wall and reposition the flame guard A Suck up the ash deposit from the...

Страница 35: ...aults and or malfunctions which may require subsequent technical assistance Requests for routine maintenance are not covered by the warranty GASKETS PELLET HOPPER LID DOOR ASH DRAWER AND BURN POT The...

Страница 36: ...36 ENGLISH HEAT EXCHANGER...

Страница 37: ...d cleaning flue pipe and T fitting B Gaskets inspections door replace if necessary burn pot and heat exchanger C Combustion chamber and heat exchanger full cleaning including ignition plug pipe D Hopp...

Страница 38: ...g and cleaning flue pipe and T fitting B Gaskets inspections door replace if necessary burn pot and heat exchanger C Combustion chamber and heat exchanger full cleaning including ignition plug pipe D...

Страница 39: ...operation the stove will enter COOLING STAND BY and then restart automatically when the conditions are right clod stove etc AIR ZONE CONTROL This message visible in the WORK phase indicates that the...

Страница 40: ...kindly asked to separate this equipment and or batteries or accumulators included from other types of waste and to arrange for disposal by the municipal waste service It is possible to ask your local...

Страница 41: ...41 ENGLISH...

Страница 42: ...42 ENGLISH...

Страница 43: ...43 ENGLISH...

Страница 44: ...ITALY 39 0445 865911 39 0445 865912 info extraflame it www lanordica extraflame com TO FIND THE SERVICE CENTRE NEAREST TO YOU CONTACT YOUR DEALER OR CONSULT THE SITE WWW LANORDICA EXTRAFLAME COM The m...

Отзывы: