Extech Instruments SL130 Скачать руководство пользователя страница 4

Version 3.1   1/06 

Sound Level Monitor Operation 

Measurement Considerations 

1.  Use a windscreen to cover the microphone in windy conditions. 

2.  Calibrate the meter often, especially if the meter has been idle for a long period of time. 

3.  Do not store/operate the meter in areas of high temperature or humidity. 

4.  Keep the meter and the microphone dry. 

5.  Avoid severe vibration when using the meter. 

6.  Remove the battery when the meter will be stored for long periods of time. 

Initial Configuration

 

1.  Connect the AC adaptor to the side or rear AC adaptor connector 

OR Install 8 AA batteries 

2.  Setting the TIME 

a) 

Press and Hold the Time SET button until the hours display 
begins to flash. 

b) 

Press the Time up arrow button until the hour is set. 

c) 

Press the SET button. The minutes display will flash. Adjust as needed. 

d) 

Press the SET button to step through and the arrow button to adjust; 
Time of day 

Hour 

Time of day 

Minutes 

Time of day 

AM / PM / 24 Hour 

Year 
Month 
Day 
Auto ON  Hour 
Auto ON  Minutes 
Auto OFF  Hour 
Auto OFF  Minute 

A/C Frequency Weighting

 

Change the Frequency Weighting by pressing the         'A/C' button. The 'A' or 'C' icon will 
appear on the display. 

With ‘A’ weighting selected, the frequency response of the meter is similar to the response 
of the  human ear. ‘A’ weighting is commonly used for environmental or hearing 
conservation programs such as OSHA regulatory testing and noise ordinance law 
enforcement. ‘C’ weighting is a much flatter response and is suitable for the sound level 
analysis of machines, engines, etc.  

Most noise measurements are performed using 'A' Weighting and SLOW Response. 

Slow/ Fast Response 

Press the         button to select Fast or Slow response as desired. F or S will appear in the 
bottom of the LCD display. 

Select FAST to capture noise peaks and noises that occur very quickly. Select the SLOW 
response to monitor a sound source that has a consistent noise level or to average quickly 
changing levels.  

Select Slow response for most applications. 

Содержание SL130

Страница 1: ... Type 2 Sound Level Meter Standards Settable High Limit with large bright High Low indication and Alarm Output Wall or Desk mountable Extra large LCD display with bargraph Maximum level display with time stamp Optional alarm kit drives remote over limit indicators ...

Страница 2: ...OFF time extends battery life to 30 days when programmed 8 hours per day The bright LED s are functional only when the AC power adaptor is used Careful use of this meter will provide years of reliable service Specifications Applicable standards Meets IEC 60651 1979 and ANSI S1 4 1983 Type 2 SLM standards Display 11 7 x 7 94cm 4 6 x 3 125 multifunction LCD Frequency bandwidth 31 5 Hz to 8 KHz Micro...

Страница 3: ...utton Rear Control Panel 1 Range select switch 2 Time set buttons 3 Limit set buttons 4 Calibration adjustment 5 A C select button 6 F S select button Side Panel 1 Alert switch Green position 2 Alert switch Red Green position 3 Alert switch Red position 4 High Low Alarm switch 5 Remote Alarm output connector 6 AC adaptor connector Rear Panel 1 Tilt stand 2 Battery compartment 3 AC Adaptor connecto...

Страница 4: ...just Time of day Hour Time of day Minutes Time of day AM PM 24 Hour Year Month Day Auto ON Hour Auto ON Minutes Auto OFF Hour Auto OFF Minute A C Frequency Weighting Change the Frequency Weighting by pressing the A C button The A or C icon will appear on the display With A weighting selected the frequency response of the meter is similar to the response of the human ear A weighting is commonly use...

Страница 5: ...play indication and output signal will remain active as long as the sound pressure level exceeds the set limit High Low LED Alert The four LEDs are used to alert users when a sound level either exceeds or goes below the Limit set point This feature is available only while the AC adaptor is used to power the meter It is disabled under battery power The LEDs will provide a steady or flashing colored...

Страница 6: ... the power switch is set to the AUTO position Calibration The sound level meter should be calibrated on a regular basis to assure that the meter s performance and microphone sensitivity has not change Some operational directives require daily calibration checks OSHA Extech offers several acoustic calibrators to perform the calibration 1 Set the meter to the 60 to 110dB or 80 to 130dB range 2 Place...

Страница 7: ...tension cable can then be plugged into the matching connectors Calibration should be performed after the cable is installed Alarm Output optional The alarm output drives the optional Remote Alarm Relay Module cable and relay when the LIMIT set point is exceeded The relay module can be used to power external warning signs QUIET signs or other indicating devices when the sound level is higher than t...

Страница 8: ...t to be free of defects in parts and workmanship for one year from date of shipment a six month limited warranty applies on sensors and cables If it should become necessary to return the instrument for service during or beyond the warranty period contact the Customer Service Department at 781 890 7440 ext 210 for authorization or visit our website at www extech com click on Contact Extech and go t...