background image

6

                                                      

RH25

EU

EN

 

v1.0

   

5/13

 

Battery

 

Replacement

 

 

When

 

the

 

low

 

battery

 

icon

 

(BAT)

 

appears

 

on

 

the

 

LCD,

 

the

 

CR

2032

 

lithium

 

button

 

battery

 

must

 

be

 

replaced.

 

The

 

battery

 

compartment

 

is

 

located

 

on

 

the

 

rear

 

of

 

the

 

meter.

 

1.

 

Use

 

a

 

coin

 

to

 

turn

 

the

 

battery

 

compartment

 

cover

 

counter

clockwise

 

to

 

open.

 

2.

 

Note

 

the

 

position,

 

orientation,

 

and

 

polarity

 

of

 

the

 

existing

 

battery

 

installation.

 

3.

 

Replace

 

the

 

CR

2032

 

Lithium

 

battery

 

following

 

the

 

same

 

position,

 

orientation,

 

and

 

polarity.

 

4.

 

Replace

 

the

 

battery

 

compartment

 

cover

 

and

 

secure

 

it

 

using

 

a

 

coin

 

to

 

turn

 

it

 

clockwise

 

Never

 

dispose

 

of

 

used

 

batteries

 

or

 

rechargeable

 

batteries

 

in

 

household

 

waste.

 

As

 

consumers,

 

users

 

are

 

legally

 

required

 

to

 

take

 

used

 

batteries

 

to

 

appropriate

 

collection

 

sites,

 

the

 

retail

 

store

 

where

 

the

 

batteries

 

were

 

purchased,

 

or

 

wherever

 

batteries

 

are

 

sold.

 

Disposal:

 

Do

 

not

 

dispose

 

of

 

this

 

instrument

 

in

 

household

 

waste.

 

The

 

user

 

is

 

obligated

 

to

 

take

 

end

of

life

 

devices

 

to

 

a

 

designated

 

collection

 

point

 

for

 

the

 

disposal

 

of

 

electrical

 

and

 

electronic

 

equipment.

  

Other

 

Battery

 

Safety

 

Reminders

 

o

 

Never

 

dispose

 

of

 

batteries

 

in

 

a

 

fire.

 

Batteries

 

may

 

explode

 

or

 

leak.

 

o

 

Never

 

mix

 

battery

 

types.

 

Always

 

install

 

new

 

batteries

 

of

 

the

 

same

 

type.

 

Specifications

 

Display

  

 

Multi

function

 

LCD

 

Measurement

 

ranges

 

Air

 

Temperature

 

20

 

to

 

50

o

C

 

(

4

 

to

 

122

o

F)

 

Heat

 

Index

  

 

46

 

to

 

205

o

C

 

(

50.8

 

to

 

401

o

F)

 

Dew

 

Point

 

 

78

 

to

 

50

o

C

 

(

108.4

 

to

 

122

o

F)

 

Wet

 

Bulb

 

 

20

 

to

 

50

o

C

 

(

4

 

to

 

122

o

F)

 

Wet

 

Bulb

 

Globe

 

25

 

to

 

54.5

o

C

 

(

13

 

to

 

130

o

F)

 

Relative

 

Humidity

 

0

 

to

 

99.9%

 

RH

 

Resolution

 

 

0.1

o

C/

 

o

F/%RH

 

Accuracy

 

Temperature

   

±0.6

o

C

 

(1

o

F)

 

Relative

 

Humidity

 

±3%RH

 

@

 

25

 

o

C

 

from

 

10

 

to

 

90%

 

RH

 

otherwise

 

±5%

 

RH

 

Power

 

supply

 

 

1

 

x

 

CR2032

 

Lithium

 

Battery

 

Dimensions

 

 

140

 

x

 

35

 

x

 

18mm

 

(5.5

 

x

 

1.4

 

x

 

0.7")

 

Weight

  

 

50g

 

(1.8

 

oz.)

 

 
 

Copyright

 

©

 

2013

 

FLIR

 

Systems,

 

Inc.

 

All

 

rights

 

reserved

 

including

 

the

 

right

 

of

 

reproduction

 

in

 

whole

 

or

 

in

 

part

 

in

 

any

 

form

 

www.extech.com

 

Отзывы: