Extech Instruments RD300 Скачать руководство пользователя страница 4

RD300-EU-EN V1.1   12/13 

Operation

 

1.

Power

 

Button:

 

Press

 

and

 

hold

 

the

 

power

 

button

 

for

 

2

 

seconds

 

to

 

turn

 

power

 

ON.

 

All

 

LEDs

will

 

light

 

and

 

the

 

start

up

 

tone

 

will

 

sound.

 

Press

 

and

 

hold

 

power

 

button

 

for

 

2

 

seconds

 

to

 

turn

off

 

the

 

meter.

 

Check

 

the

 

battery

 

if

 

the

 

meter

 

does

 

not

 

switch

 

ON.

2.

Warm

Up:

 

The

 

detector

 

will

 

automatically

 

start

 

heating

 

the

 

sensor

 

after

 

power

on.

 

During

the

 

90

 

second

 

warm

up,

 

the

 

Leak

 

Level

 

LEDs

 

and

 

Power

 

LED

 

will

 

be

 

lit

 

in

 

cyclic

 

fashion

 

and

the

 

meter.

 

After

 

the

 

warm

up,

 

the

 

audible

 

tone

 

will

 

sound

 

and

 

the

 

Power

 

LED

 

will

 

remain

 

lit.

At

 

this

 

time

 

the

 

detector

 

is

 

ready

 

to

 

find

 

leaks.

3.

Sensitivity

 

Range

 

Button:

 

Press

 

the

 

Sensitivity

 

Range

 

button

 

to

 

change

 

sensitivity

 

levels.

 

The

High,

 

medium,

 

or

 

low

 

LED

 

will

 

light

 

depending

 

upon

 

the

 

user’s

 

selection.

 

The

 

detector

 

will

automatically

 

default

 

to

 

the

 

previous

 

sensitivity

 

level

 

after

 

warm

up.

 

4.

Reset

 

Button:

 

Press

 

the

 

'R'

 

button

 

once

 

to

 

reset

 

the

 

meter;

 

the

 

reset

 

LED

 

will

 

flash

 

once.

5.

Mute

 

button:

 

Press

 

the

 

Mute

 

button

 

to

 

toggle

 

the

 

audio

 

on

 

and

 

off.

 

The

 

mute

 

LED

 

is

 

on

when

 

the

 

audio

 

is

 

switched

 

OFF

 

(muted).

6.

Tip

 

Work

 

Light

 

LED

 

Button:

 

Press

 

tip

 

light

 

LED

 

button

 

to

 

switch

 

the

 

probe

 

tip

 

work

 

light

 

ON

or

 

OFF.

7. Pass

 

the

 

sensor

 

tip

 

near

 

the

 

potential

 

source

 

of

 

leak

 

and

 

gage

 

the

 

meter’s

 

response

 

by

observing

 

the

 

color

 

coded

 

LEDs.

 

Green

 

LEDs

 

represent

 

the

 

absence

 

of

 

a

 

leak

 

or

 

a

 

very

 

small

leak,

 

yellow

 

LEDs

 

represent

 

a

 

moderate

 

leak,

 

and

 

red

 

LEDs

 

represent

 

the

 

detection

 

of

 

a

 

large

leak.

Probe

 

and

 

LED

 

Work

 

Light

 

Replacement

 

To

 

replace

 

the

 

3V

 

LED

 

work

 

light

 

or

 

the

 

sensor

 

please

 

refer

 

to

 

the

 

diagram

 

below.

 

Please

 

switch

 

off

 

the

 

detector

 

before

 

removing

 

sensor.

  

Diode

 

sensor

 

tip

 ‐ 

part

 

number

 

RD300

S.

  

LED

 

work

 

light

 ‐ 

part

 

number

 

RD300

L.

 

Notes:

 

1.

The

 

life

 

of

 

the

 

sensor

 

is

 

1

 

year

 

under

 

normal

 

use;

 

if

 

a

 

sensor

 

is

 

exposed

 

to

 

a

 

100

 

ppm

refrigerant,

 

the

 

sensitivity

 

characteristics

 

of

 

the

 

sensor

 

may

 

be

 

affected.

 

2.

Make

 

sure

 

there

 

are

 

no

 

water

 

droplets

 

or

 

dust

 

on

 

the

 

surface

 

of

 

the

 

sensor.

netzerotools.com

netzerotools.com

Содержание RD300

Страница 1: ...User Guide Refrigerant Leakage Detector Model RD300 netzerotools com netzerotools com netzerotools com Extech RD300 Air Conditioning AC Refrigerant Leak Detector ...

Страница 2: ...ld immunity test Be sure to follow the safety points below Failure to do so could cause personal injury or damage to the meter Please read this manual carefully to ensure safe and correct use of this meter before using Do not attempt to repair this device only qualified personnel should repair this device Do not force the flexible tube to bend over its angle limit Doing so can damage the device Do...

Страница 3: ...frigerants using a heated diode sensor LED work lights with on off switch to allow viewing in dark environments High Medium Low color coded LED indication with sensitivity of 0 25 oz year Audible and visual alerts with mute button Low battery indication Field replacement sensor and LED work light tip Meter Description 1 ON OFF button hold for 2 seconds 2 Color coded LED Level Indicators bottom LED...

Страница 4: ...utton once to reset the meter the reset LED will flash once 5 Mute button Press the Mute button to toggle the audio on and off The mute LED is on when the audio is switched OFF muted 6 Tip Work Light LED Button Press tip light LED button to switch the probe tip work light ON or OFF 7 Pass the sensor tip near the potential source of leak and gage the meter s response by observing the color coded LE...

Страница 5: ...y cover and replace the battery 3 Make sure the battery cover is snapped into place securely before operating the meter Never dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dispose o...

Страница 6: ...r 28g yr Warm up Time 90 seconds Auto Power OFF Automatic shut off after 10 minutes Low Battery Indication LOW BATT light switches ON Power Supply 9V Battery Battery Life 13 hours of continuous use Operating Conditions 0 C to 50 C 32 F to 122 F 80 RH Storage Conditions 10 C to 60 C 14 F to 140 F 70 RH Flexible Probe Length 450mm 18 Dimensions Weight 184 x 70 x 40 mm 7 2 x 2 8 x 1 6 Weight 280g 10 ...

Отзывы: