background image

MO55W-en-GB_V1.1   11/18 

Wireless Communication 

Overview 

We ship the MO55W with a Bluetooth® Wireless Datalogging Module (DAT12) installed. The 
DAT12 transmits real-time readings, logged readings, and high/low alarm data to paired iOS® or 

Android™ devices using the free ExView

® W-Series

 application

. The DAT12 stores >15k readings. 

Installing/Replacing a Wireless Module  

The wireless modules install in the rear battery compartment. To install a module: 

1.

 

Ensure that the meter is OFF before installing/replacing a wireless module 

2.

 

Remove the battery compartment cover and remove the battery 

3.

 

Insert the module in the slot at the top of the compartment with the arrow correctly 
oriented at the top of the module 

4.

 

Attach the module to the 8-pin connector inside the compartment 

5.

 

Replace the battery and the battery compartment cover before use  

Obtaining the Free Application 

For iOS devices, download the ExView® W-Series application from the Apple App store.  
For Android devices, download the ExView® W-Series application from the Google Play

™ s

tore. 

Using the Application 

1.

 

Turn the meter power ON and select a measurement function on the meter. 

2.

 

Long press the 

 button to start (or stop) wireless transmission (the 

 

display icon will 

appear when the meter is transmitting). 

3.

 

On your smart device, tap the 

ExView® W 

application icon to start the App. (Bluetooth® 

must be enabled on your smart device) 

4.

 

Tap the search icon located next to ‘Devices’. The App will search for available devices. 

Look 

for the meter icon on the remote device. When the meter appears in the device list, tap it 
to connect the meter to the App. 

5.

 

For more information, please refer to the ExView® W-Series Help Guide by tapping on the 
Extech icon and then tapping the Help Guide link, or locate the document on the 
extech.com/exvieww web page. 

6.

 

Please not

e that some Android™ devices require that you switch ON the device’s location 

setting before the ExView® W app can establish a connection with the wireless meters.   

FCC Compliance 

A wireless module must be installed in the meter before the module can communicate 

with iOS®/Android™

 phones and tablets via Bluetooth® using the 

ExView® W

 application. 

 
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:  
1. This device may not cause harmful interference.  
2. This device must accept any interference received, including interference that may cause undesired 
operation.  
 
IC: 1590A-MO55W 
FCC ID: IWK-MO55W 

Содержание MO55W

Страница 1: ...USER MANUAL Model MO55W Wireless Datalogging Dual Moisture Meter Pin and Pinless Moisture Measurements...

Страница 2: ...e app is available from the Apple App store and Google Play store We ship this meter fully tested and calibrated and with proper use it will provide years of reliable service Please visit our website...

Страница 3: ...isplay Description 1 Moisture droplet icons 1 drop for low moisture 2 for moderate and 3 for high 2 Wood mode 3 Building material mode 4 Beeper active icon 5 Moisture reading digits 6 Unit of measure...

Страница 4: ...are also very accurate for best results use the pinless mode to compare dry area readings to areas of unknown moisture levels 7 View the displayed reading and the number of moisture droplet icons One...

Страница 5: ...ts through the holes at the top of the cap Expected result Wood 17 0 to 19 0 Building 15 5 to 17 5 If the reading exceeds these ranges replace the battery and retry If the meter continues to read inac...

Страница 6: ...n on the meter 2 Long press the button to start or stop wireless transmission the display icon will appear when the meter is transmitting 3 On your smart device tap the ExView W application icon to st...

Страница 7: ...e the rear battery compartment cover by pushing the compartment latch 2 Replace the 9V battery observing correct polarity 3 Replace the compartment door securely 4 Dispose of battery responsibly and w...

Страница 8: ...materials Resolution 0 1 Accuracy Pin mode 3 rdg 5 digits Electrode Pin Length 10mm 0 4 Electrode Pin Type Stainless steel Integrated replaceable Auto Power OFF After approx three 3 minutes Power Sup...

Отзывы: