LCD Backlight ON/OFF 

With the meter switched ON, pressing and holding both front panel buttons (MODE and 
HOLD) switches the LCD backlight ON and OFF. 

Data Hold feature 

The Data Hold function freezes the reading in the display. Press the HOLD key 
momentarily to activate the Data Hold function. The reading will freezee and the ‘key’ 
display icon will appear. Press the HOLD key again to exit the Data Hold function (the 
‘key’ display icon will switch off).  

 

Meter Setup 

 

 

To enter the setup mode: 

With the meter switched OFF, press and hold both front panel buttons (MODE and 
HOLD buttons) simultaneously for two seconds. The display should now read ‘0 = 
x’ where ‘0’ is the OPTION and ‘x’ is the SETTING. 

 

Use the MODE (right arrow) button to change the SETTING. 

 

Use the HOLD button to scroll through the OPTIONS. 

 

The available OPTIONS and SETTINGS: 

  

OPTIONS 

SETTINGS 

SET-UP INFORMATION 

Switches all settings to ‘0’ (Factory Default*) 

Others settings can now be changed. In addition, 
Backlight switches ON for 30 seconds and then 
automatically switches OFF. 

Audible alert beeps with increasing frequency from a 
nominal 17.0 (REL) or 17% (WME) measurement value 
upwards 

Audible alert divided into 3 frequency levels 

Audible alert beeps when user switches from one mode 
to another 

Beeper OFF. Audio alert display symbol switches OFF 

Auto Switch OFF is not active. User must manually 
switch the unit OFF 

Auto Switch OFF active. Switches OFF after 3 minutes 

Auto Switch OFF active. Switches OFF after 5 minutes 

Auto Switch OFF active. Switches OFF after 10 minutes 

Backlight OFF 

Backlight ON 

*FACTORY DEFAULT SETTINGS: 0=0, 1=0, 2=0, 3=0 

Содержание MO265

Страница 1: ...User Guide Dual Moisture Meter Pro Pin Pinless Moisture Meter with remote probe Model MO265...

Страница 2: ...de years of reliable service Features WME wood moisture equivalent pin moisture reading Relative REL pinless moisture reading for non invasive measurement Remote probe measurements Digital LCD readout...

Страница 3: ...ated beneath the protective cap Calibration source located at the top of protective cap A tripod mount is located on the rear of the remote probe head LCD Display Description 1 Measurement reading 2 B...

Страница 4: ...of the meter The cap can be affixed to the side of the meter using the protective cap holders 6 2 Press the key to turn the meter ON OFF 3 Press the MODE key to select the Wood Moisture Equivalent WM...

Страница 5: ...both at the same time 1 Connect the Remote Probe to the right side of the meter using the RJ 11 plug at the end of the Remote Probe cable 2 Remove the protective cap from the remote probe to expose t...

Страница 6: ...switch back to the normal display mode 4 The display should now read zero indicating that the calibration is complete 5 If an E32 error is displayed try the zero calibration again with the pins furthe...

Страница 7: ...ght arrow button to change the SETTING Use the HOLD button to scroll through the OPTIONS The available OPTIONS and SETTINGS OPTIONS SETTINGS SET UP INFORMATION 0 0 Switches all settings to 0 Factory D...

Страница 8: ...ary but never use abrasives or solvents Prevent dirt from accumulating at the electrode pins Specifications Display Backlit LCD digital display and tri color LED bargraph scale Resolution 0 1 Accuracy...

Отзывы: