Страница 2: ...alibrated and with proper use will provide years of reliable service Please visit our website www extech com to check for the latest version of this User Guide Product Updates Product Registration and...

Страница 3: ...se be subjected to particularly hazardous voltages For maximum safety the meter and its test leads should not be handled when these terminals are energized This symbol indicates that a device is prote...

Страница 4: ...the skin Use protective gloves when handling Do not short circuit the batteries Do not throw batteries into a fire This meter has been designed for safe use but must be operated with caution The rules...

Страница 5: ...d the maximum reading Press again MIN will appear The meter will display and hold the minimum reading To exit press and hold MAX MIN for 2 seconds REL Relative button The displayed value at the time o...

Страница 6: ...us icon 12 APO Auto Power OFF active 13 Measurement reading digits 14 Non contact voltage detector displays EF in reading area 15 Auto Range is shown in Auto Range mode 16 MAX MIN memory active 17 Dat...

Страница 7: ...erform the following 1 Press the RANGE button The AUTO RANGE display indicator will turn off 2 Press the RANGE button to step through the available ranges 3 To exit the Manual Ranging mode and return...

Страница 8: ...return to Auto Range Mode Read the voltage in the display AC VOLTAGE MEASUREMENTS WARNING Risk of Electrocution The probe tips may not be long enough to contact the live parts inside some 240V outlet...

Страница 9: ...t lead banana plug into the negative COM jack Insert red test lead banana plug into the positive V jack 3 Press and hold the VFC button until the meter beeps and VFC is briefly displayed The meter is...

Страница 10: ...current measurements for longer than 30 seconds Allow 15 minutes between tests Exceeding 30 seconds may cause damage to the meter and or the test leads 1 Insert black test lead banana plug into the ne...

Страница 11: ...ments up to 600mA AC set the function switch to the mA position and insert the red test lead banana plug into the A mA jack 4 For current measurements up to 10A AC set the function switch to the A pos...

Страница 12: ...use the Relative mode to null the test lead error Check the test leads for loosening or other breakage and verify that the lead resistance is 0 5 or less by shorting the leads and viewing the displaye...

Страница 13: ...e batteries and unplug the line cords 1 Set the rotary function switch to the Capacitance symbol position 2 Insert the black test lead banana plug into the negative COM jack Insert the red test lead b...

Страница 14: ...in the Non Contact Voltage Detector mode if the meter does not power up when the function dial is set to the NCV position 1 Set the rotary function switch to the NCV position 2 Hold the meter top near...

Страница 15: ...oved to prevent damage to the unit BATTERY INSTALLATION WARNING To avoid electric shock disconnect the test leads from any source of voltage before removing the battery cover 1 Turn power off and disc...

Страница 16: ...low the battery compartment replace fuse F1 FF0 5A H 600V CE 6x32mm 6 Remove the remaining two Phillips head screws located on the back of the meter near the bottom 7 Open the meter housing by pulling...

Страница 17: ...e 600Vrms Frequency response 45 1kHz for VFC 45 400Hz True RMS All AC voltage ranges are specified from 5 of range to 100 of range Crest Factor 3 at full scale up to 400V decreasing linearly to 1 5 at...

Страница 18: ...nt accuracy Frequency electronic 9 999Hz 9 999MHz 0 001Hz 0 001MHz 0 1 reading 4 digits Duty Cycle 1 99 0 1 Not defined Frequency and Duty Cycle notes Overload protection 600V Input range sensitivity...

Страница 19: ...2 fuse 6x25mm F 10A H 600V CE Operating Temperature 0 o C to 40 o C 32 o F to 104 o F Storage Temperature 10o C to 50 o C 14 o F to 122 o F Operating Humidity 75 RH for 0 30 o C 32 86 o F 50 RH for 30...