background image

Instruction Sheet 

Model TP870
Type K Bead Wire Thermocouple Probe 

WARNING: 

To avoid electric shock, do not probe into or near live electrical circuits with the 

thermocouple probe..

Sensor Type 

Type K thermocouple (Chromel – Alumnel) 

Temperature range

 

-40 to 482

o

F (-40 to 250

o

C) 

Lead length

 

39” (1m) 

Connector 

subminiature 

Note: 

This probe is not UL listed 

more infor for 

Extech MN26T

Phone: 01235 838 555

Email: [email protected]

Web. www.airconcern.co.uk

Air Concern Ltd, Building 173 Curie Avenue Harvell Didcot, Oxfordshire

Содержание MN26

Страница 1: ...User s Manual MiniTecTM Series Model MN26 Model MN26T includes temperature probe Mini Autoranging MultiMeter...

Страница 2: ...damage before use 5 Do not exceed the maximum rated input limits 6 Use great care when making measurements if the voltages are greater than 25VAC rms or 35VDC These voltages are considered a shock haz...

Страница 3: ...reading 5 digits 999 9Hz 0 1Hz 9 999kHz 0 001kHz 99 99kHz 0 01kHz 999 9kHz 0 1kHz 1 2 reading 2 digits 9 999MHz 0 001MHz 1 5 reading 4 digits Frequency Sensitivity 0 8V rms min 20 to 80 duty cycle and...

Страница 4: ...AA batteries Fuses mA A ranges 0 5A 250V fast blow 10A range 10A 250V fast blow Operating Temperature 32 o F to 122 o F 0 o C to 50 o C Storage Temperature 4 o F to 140 o F 20 o C to 60 o C Relative H...

Страница 5: ...and read the voltage on the display AC or DC Current Measurements CAUTION Do not make current measurements on the 10A scale for longer than 30 seconds followed by a 15 minute cool down period Exceedi...

Страница 6: ...robe into the sub miniature temperature socket see separate instruction sheet at the end of this manual 2 Turn the rotary switch to the o C or o F position 3 Read the temperature on the display Note A...

Страница 7: ...d reference value A reference voltage current etc can be stored and measurements made in comparison to that value The displayed value is the difference between the reference value and the measured val...

Страница 8: ...removed to prevent damage to the unit Battery Replacement WARNING To avoid electric shock disconnect the test leads from any source of voltage before removing the battery fuse cover 1 Disconnect the t...

Страница 9: ...returned to Extech The sender is responsible for shipping charges freight insurance and proper packaging to prevent damage in transit This warranty does not apply to defects resulting from action of...

Страница 10: ...e thermocouple probe Sensor Type Type K thermocouple Chromel Alumnel Temperature range 40 to 482 o F 40 to 250 o C Lead length 39 1m Connector subminiature Note This probe is not UL listed more infor...

Отзывы: