DC

 

Voltage

 

Measurements

 

 

 

1.

 

Insert

 

the

 

black

 

test

 

lead

 

banana

 

plug

 

into

 

the

 

negative

 

(COM)

 

jack

 

and

 

the

 

red

 

test

 

lead

 

banana

 

plug

 

into

 

the

 

positive

 

(V/

)

 

jack.

 

2.

 

Move

 

the

 

Function

 

Switch

 

to

 

the

 

V

 

position.

  

3.

 

Press

 

the

 

MODE

 

button

 

to

 

select

 

DC

 

if

 

necessary.

 

4.

 

Touch

 

the

 

test

 

probe

 

tips

 

to

 

the

 

circuit

 

under

 

test.

 

Be

 

sure

 

to

 

observe

 

the

 

correct

 

polarity

 

(red

 

lead

 

to

 

positive,

 

black

 

lead

 

to

 

negative).

 

5.

 

Read

 

the

 

voltage

 

in

 

the

 

display.

 

The

 

display

 

will

 

indicate

 

the

 

proper

 

decimal

 

point

 

and

 

value.

 

If

 

the

 

polarity

 

is

 

reversed,

 

the

 

display

 

will

 

show

 

(

)

 

minus

 

before

 

the

 

value.

 

6.

 

The

 

meter

 

is

 

capable

 

of

 

detecting

 

DC

 

voltages

 

to

 

600V.

 

7.

 

When

 

voltage

 

is

 

measured,

 

the

 

NCV

 

voltage

 

detect

 

LED

 

will

 

be

 

lit.

 

 

Fig

6

 

DC

 

VOLTAGE

 

MEASUREMENT

 

 

 

 

Resistance

 

Measurements

 

Cautions

:

 

Switch

 

OFF

 

power

 

to

 

the

 

device

 

under

 

test

 

before

 

measuring.

 

Do

 

not

 

test

 

on

 

circuits

 

or

 

devices

 

where

 

60VDC

 

or

 

30VAC

 

is

 

present.

 

1.

 

Insert

 

the

 

black

 

test

 

lead

 

banana

 

plug

 

into

 

the

 

negative

 

(COM)

 

jack.

 

Insert

 

the

 

red

 

test

 

lead

 

banana

 

plug

 

into

 

the

 

positive

 

(V/

)

 

jack.

 

2.

 

Turn

 

the

 

Function

 

Switch

 

to

 

the

 Ω 

position.

 

3.

 

Use

 

the

 

MODE

 

button

 

to

 

select

 

the

 Ω 

icon

 

on

 

the

 

display

 

indicating

 

resistance

 

only

 

(without

 

the

 

audible

 

continuity

 

icon

 

showing).

  

4.

 

Touch

 

the

 

test

 

probe

 

tips

 

across

 

the

 

circuit

 

or

 

part

 

under

 

test.

 

It

 

is

 

best

 

to

 

disconnect

 

one

 

side

 

of

 

the

 

part

 

under

 

test

 

so

 

the

 

rest

 

of

 

the

 

circuit

 

will

 

not

 

interfere

 

with

 

the

 

resistance

 

reading.

 

5.

 

Read

 

the

 

resistance

 

in

 

the

 

display.

 

The

 

display

 

will

 

indicate

 

the

 

proper

 

decimal

 

point

 

and

 

value.

 

 

Fig

7

 

RESISTANCE

 

MEASUREMENT

 

Содержание MA61

Страница 1: ...USER GUIDE True RMS Mini Clamp Meters MA61 60A AC Clamp Meter MA63 60A AC DC Clamp Meter...

Страница 2: ...ur website www extech com to check for the latest version of this User Guide Product Updates Product Registration and Customer Support Features True RMS for accurate readings of noisy distorted or non...

Страница 3: ...protective finger guard while testing 4 Please check the clamp meter housing buttons switches and insulated wires for cracks or other damage before each use Service or replace if necessary 5 Please r...

Страница 4: ...tton on MA63 10 Display Hold backlight button 11 Jaw trigger open close control Fig 1 Meter Parts 1 2 3 4 5 6 7 8 9 10 11 Control Buttons Description Button Description Press and hold to select VFC va...

Страница 5: ...ent 7 POWER OFF selection 8 Function Selector Dial MODEL MA63 9 NCV Non Contact Voltage Detector 10 60A AC with Frequency or DC Measurements 11 600mA AC with Frequency or DC Measurements 12 6000mA AC...

Страница 6: ...APO icon switches off when APO is disabled ZERO REL Zero MA63 and Relative MA61 functions VFC Variable Frequency Control low pass filter for AC Voltage Current EF NCV Non Contact Voltage Detector EF...

Страница 7: ...omatically switches off after 15 minutes of inactivity Before switching off the meter beeps several times to alert the user To disable APO hold down the MODE button while powering up the meter The met...

Страница 8: ...t stop measuring with the low pass filter 6 Read the ACA value on the LCD DC Current Measurements MA63 only WARNING To avoid electric shock disconnect the test leads from the meter before making curre...

Страница 9: ...AC DC between the meter s terminals and earth ground CAUTION When connecting the test leads to the circuit or device under test connect the black lead before the red when removing the test leads remov...

Страница 10: ...asured the NCV voltage detect LED will be lit Fig 6 DC VOLTAGE MEASUREMENT Resistance Measurements Cautions Switch OFF power to the device under test before measuring Do not test on circuits or device...

Страница 11: ...discharge the capacitor under test before measuring Do not test on circuits or devices where 60VDC or 30VAC is present 1 Set the function switch to the capacitance position 2 Insert the black test le...

Страница 12: ...the LCD when in Diode test mode 3 Touch the test probe tips to the diode or semiconductor junction under test Note the meter reading 4 Reverse the test lead polarity by reversing the red and black le...

Страница 13: ...he possibility that voltage is present Please use caution 1 Turn the Function switch to the NCV position to access the Non Contact Voltage Detect mode 2 Note the voltage detection display icon NCV and...

Страница 14: ...sconnect the test leads from the meter turn the meter off and unclamp the meter from any conductors before attempting to change the batteries 1 When the low battery symbol appears on the LCD the batte...

Страница 15: ...lative Display rate 2 3 readings second Battery Two 1 5V AAA batteries Operating temperature 0 0 C to 40 0 C 32 0 F to 104 0 F Operating Humidity 75 RH 0 30C 32 0 F to 86 0 F 50 RH 30 40C 86 0 F to 10...

Страница 16: ...circuit AC Crest Factor may reach 3 0 at 4000 counts for non sinusoidal waveforms the Crest Factor error increases per the following Add 3 when the crest factor is 1 2 Add 5 when the crest factor is 2...

Страница 17: ...ference only Resistance Resolution Accuracy Overload 600 0 0 1 1 0 2d 600V 6 000k 1 0 8 2d 600V 60 00k 10 600V 600 0k 100 600V 6 000M 1k 1 2 3d 600V 60 00M 10k 1 5 5d 600V Capacitance Resolution Accur...