MA3110-en-GB_V1.0   12/16 

15 

GENERAL SPECIFICATIONS 

Clamp 

Flexible type with locking mechanism 

 

8mm (0.3”) coil diameter 

 

300mm (11.8”) flexible cable length  

Display 

6000 count LCD with multi-function indicators 

 

33.5 x 18.7mm (1.3 x 0.7”) display size 

 

Auto range 600.0A and 3000A AC 

Sampling rate 

0.5 to 1 second 

Low Battery indication 

Low voltage display alerts 

Over-range indication 

‘OL’ display 

AC bandwidth 

50/60Hz (sine wave) 

AC response 

True RMS 

Operating Temperature and Humidity 

 

0~50

C (32~122

F); 80%RH maximum  

 

Battery 

Two “AAA” 1.5V batteries 

Battery consumption 

21.1mA approximately 

Auto power OFF 

After approx. 15 minutes of inactivity 

Dimensions (W x H x D) 

290 x 135 x 27.8 mm (11.4 x 5.3 x 1.09”) 

Weight 

208g (0.46 lbs.) without battery 

Safety Standards 

IEC61010-1, 3

rd

 Edition (2010); Pollution degree 2; Altitude 2000m 

(6562’) maximum; Indoor use only 

Voltage/Category Rating 

1000V CAT III, 600V CAT IV 

Current Rating 

  3000A 

Probes 

  Listed IEC61010-031 Probes Only 

 

 

 

Copyright © 2016 FLIR Systems, Inc. 

All rights reserved including the right of reproduction in whole or in part in any form 

ISO-9001 Certified 

www.extech.com 

 

Содержание MA3110

Страница 1: ...USER MANUAL 3000A TRUE RMS AC Flexible Clamp Meter Model MA3110 Additional User Manual Translations available at www extech com...

Страница 2: ...the latest version of this User Guide Product Updates Product Registration and Customer Support Features 600A and 3000A AC True RMS Current Measurement ranges AC True RMS and DC Voltage Measurements...

Страница 3: ...s identify hazardous conditions and actions that could cause BODILY HARM or DEATH Individual protective equipment should be used if HAZARDOUS LIVE parts in the installation where measurements are to b...

Страница 4: ...OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which measures are taken to limit the transient over voltages to an appropriate low level Note Examples include protected electronic...

Страница 5: ...a Hold AUTO Automatic Range mode AC Alternating Current DC Direct Current Low battery icon flashing when measurements cannot be expected to be in specification Continuity alert beeper V Unit for Volta...

Страница 6: ...an be made Refer to the battery replacement procedure in the maintenance section Automatic Power OFF The meter switches OFF automatically after a 15 minute period of inactivity To disable the Auto Pow...

Страница 7: ...efore the black lead 1 Connect the black test lead into the COM terminal 2 Connect the red test lead into the V terminal 3 Power the meter using the power button 4 Put the function switch to the V pos...

Страница 8: ...A with the function switch The display will show the automatic range icon AUTO 3 Turn the knurled clamp lock mechanism counter clockwise to release the flexible clamp 4 Fully enclose only one conducto...

Страница 9: ...onnect the red test lead into the terminal 3 Power the meter using the power button 4 Put the function switch to the position 5 The display will show the AUTO icon Auto Range mode 6 Press the M Mode b...

Страница 10: ...ead into the ohms terminal 3 Power the meter using the power button 4 Put the function switch to the ohms position 5 The display will show the AUTO icon Auto Range mode 6 Press the M Mode button to se...

Страница 11: ...e M Mode button to select diode mode The display will show the manual mode symbol MANU 7 When connected as shown in test position 1 a forward current flow is established and the approximate diode forw...

Страница 12: ...he red test lead into the terminal 3 Power the meter using the power button 4 Put the function switch to the position 5 The display will show the AUTO icon Auto Range mode 6 Press the M Mode button to...

Страница 13: ...ies observing correct polarity 4 Re attach the battery compartment cover 5 Secure the battery compartment with the screw Never dispose of used batteries or rechargeable batteries in household waste As...

Страница 14: ...r AC Current Measurements 50 60Hz Resistance 600 0 1 1 0 5 digits 6K 0 001K 1 5 5 digits 60K 0 01K 600K 0 1K 6M 0 001M 60M 0 01M 3 0 5 digits Overload protection 350 V DC AC This is the resolution whe...

Страница 15: ...emperature and Humidity 0 50 C 32 122 F 80 RH maximum Battery Two AAA 1 5V batteries Battery consumption 21 1mA approximately Auto power OFF After approx 15 minutes of inactivity Dimensions W x H x D...

Отзывы: