USER MANUAL
3000A TRUE RMS AC Flexible Clamp Meter
Model MA3110
Additional User Manual Translations available at
www.extech.com
Страница 1: ...USER MANUAL 3000A TRUE RMS AC Flexible Clamp Meter Model MA3110 Additional User Manual Translations available at www extech com...
Страница 2: ...the latest version of this User Guide Product Updates Product Registration and Customer Support Features 600A and 3000A AC True RMS Current Measurement ranges AC True RMS and DC Voltage Measurements...
Страница 3: ...s identify hazardous conditions and actions that could cause BODILY HARM or DEATH Individual protective equipment should be used if HAZARDOUS LIVE parts in the installation where measurements are to b...
Страница 4: ...OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which measures are taken to limit the transient over voltages to an appropriate low level Note Examples include protected electronic...
Страница 5: ...a Hold AUTO Automatic Range mode AC Alternating Current DC Direct Current Low battery icon flashing when measurements cannot be expected to be in specification Continuity alert beeper V Unit for Volta...
Страница 6: ...an be made Refer to the battery replacement procedure in the maintenance section Automatic Power OFF The meter switches OFF automatically after a 15 minute period of inactivity To disable the Auto Pow...
Страница 7: ...efore the black lead 1 Connect the black test lead into the COM terminal 2 Connect the red test lead into the V terminal 3 Power the meter using the power button 4 Put the function switch to the V pos...
Страница 8: ...A with the function switch The display will show the automatic range icon AUTO 3 Turn the knurled clamp lock mechanism counter clockwise to release the flexible clamp 4 Fully enclose only one conducto...
Страница 9: ...onnect the red test lead into the terminal 3 Power the meter using the power button 4 Put the function switch to the position 5 The display will show the AUTO icon Auto Range mode 6 Press the M Mode b...
Страница 10: ...ead into the ohms terminal 3 Power the meter using the power button 4 Put the function switch to the ohms position 5 The display will show the AUTO icon Auto Range mode 6 Press the M Mode button to se...
Страница 11: ...e M Mode button to select diode mode The display will show the manual mode symbol MANU 7 When connected as shown in test position 1 a forward current flow is established and the approximate diode forw...
Страница 12: ...he red test lead into the terminal 3 Power the meter using the power button 4 Put the function switch to the position 5 The display will show the AUTO icon Auto Range mode 6 Press the M Mode button to...
Страница 13: ...ies observing correct polarity 4 Re attach the battery compartment cover 5 Secure the battery compartment with the screw Never dispose of used batteries or rechargeable batteries in household waste As...
Страница 14: ...r AC Current Measurements 50 60Hz Resistance 600 0 1 1 0 5 digits 6K 0 001K 1 5 5 digits 60K 0 01K 600K 0 1K 6M 0 001M 60M 0 01M 3 0 5 digits Overload protection 350 V DC AC This is the resolution whe...
Страница 15: ...emperature and Humidity 0 50 C 32 122 F 80 RH maximum Battery Two AAA 1 5V batteries Battery consumption 21 1mA approximately Auto power OFF After approx 15 minutes of inactivity Dimensions W x H x D...