background image

 

MA160

en

GB_V1.0

   

10/15

 

16

Capacitance

 

Measurements

 

 

WARNING:

 

To

 

avoid

 

electric

 

shock,

 

remove

 

power

 

to

 

the

 

circuit

 

under

 

test

 

and

 

discharge

 

the

 

capacitor

 

under

 

test

 

before

 

measuring.

  

Do

 

not

 

test

 

on

 

circuits

 

or

 

devices

 

where

 

60VDC

 

or

 

30VAC

 

is

 

present.

 

1.

 

Set

 

the

 

function

 

switch

 

to

 

the

 

 

capacitance

 

position.

 

2.

 

Insert

 

the

 

black

 

test

 

lead

 

banana

 

plug

 

into

 

the

 

negative

 

COM

 

jack

  

and

 

the

 

red

 

test

 

lead

 

banana

 

plug

 

into

 

the

 

positive

 

 

jack.

 

3.

 

Press

 

the

 

M

 

button

 

to

 

select

 

the

 

unit

 

of

 

measure

 

symbol

 

F

.

 

4.

 

Touch

 

the

 

test

 

probe

 

tips

 

across

 

the

 

part

 

under

 

test.

 

5.

 

For

 

small

 

capacitance

 

values,

 

use

 

the

 

Relative

 

mode

   

to

 

remove

 

test

 

lead

 

and

 

probe

 

capacitance.

 

6.

 

Read

 

the

 

capacitance

 

value

 

in

 

the

 

display.

 

7.

 

The

 

display

 

will

 

indicate

 

the

 

proper

 

decimal

 

point

 

and

 

value.

 

 

Fig

 

4

7

 

CAPACITANCE

 

MEASUREMENTS

 

 

Capacitance

 

Measurement

 

Notes:

 

 

The

 

display

 

will

 

show

 

“OL”

 

if

 

a

 

capacitor

 

is

 

short

 

circuited

 

or

 

if

 

the

 

measured

 

capacitance

 

>

 

maximum

 

range

 

of

 

the

 

instrument.

 

 

Capacitance

 

measurements

 

>

 

600

μ

F

 

may

 

require

 

several

 

seconds

 

to

 

obtain

 

a

 

stable

 

reading.

 

 

In

 

order

 

to

 

ensure

 

measurement

 

accuracy,

 

discharge

 

residual

 

charges

 

before

 

measuring

 

capacitance;

 

Use

 

maximum

 

safety

 

when

 

working

 

with

 

high

 

voltage

 

capacitors

 

to

 

prevent

 

damage

 

to

 

the

 

instrument

 

and

 

risk

 

to

 

personal

 

safety.

 

 

Disconnect

 

test

 

leads

 

and

 

circuit

 

under

 

test

 

after

 

measurements

 

are

 

completed.

 

Shop for Extech products at:

1.888.610.7664

ShopExtech

.com

Содержание MA160

Страница 1: ...USER GUIDE True RMS 200A AC DC Open Jaw Clamp Meter Model MA160 Shop for Extech products at 1 888 610 7664 ShopExtech com...

Страница 2: ...old 9 Test Lead Considerations 9 Voltage Measurements 10 AC Voltage Measurements 10 DC Voltage Measurements 11 Current Measurements Using the Clamp 12 Non Contact Voltage Detector 13 Resistance Measur...

Страница 3: ...fully tested and calibrated and with proper use will provide years of reliable service Please visit our website www extech com to check for the latest version of this User Guide Product Updates Produc...

Страница 4: ...prevent electrical shock and damage to the Clamp meter Use caution working with voltages above 30 VAC RMS 42 VAC peak or 60 VDC These voltages pose a shock hazard To avoid misleading readings that co...

Страница 5: ...mit the transient over voltages to an appropriate low level Note Examples include protected electronic circuits OVERVOLTAGE CATEGORY II Equipment of OVERVOLTAGE CATEGORY II is energy consuming equipme...

Страница 6: ...NCV alert LED lamp 5 Work Light switch 6 Rotary function switch 7 Mode M button 8 Relative DCA Zero button 9 HOLD and Backlight button 10 Display 11 Test lead jacks Note Battery compartment on back of...

Страница 7: ...Units of measure 2 DCA Zero 3 Relative mode 4 Data hold 5 Alternating Current 6 Direct Current 7 Automatic range 8 Continuity 9 Diode 10 Capacitance 11 Non Contact Voltage Detector 12 Auto power off...

Страница 8: ...In DCA mode press to zero the display press and hold to exit the zero Press and hold this button to activate deactivate the LCD backlight Momentary presses switch DATA HOLD ON or OFF Function Switch D...

Страница 9: ...button to switch the backlight ON or OFF Note that excessive use of the backlight will shorten the battery life Work Light With the meter powered ON press the Work Light button on the right side of th...

Страница 10: ...the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive V jack 2 Turn the function switch to the position Use the M button to select AC 3 Read t...

Страница 11: ...her or not to use the test lead probe covers 5 Touch the test probe tips to the circuit under test Be sure to observe the correct polarity red lead to positive black lead to negative 6 Read the digita...

Страница 12: ...function switch to the position 3 Use the M button to select AC or DC For DC press ZERO to remove any residual magnetism and to null the display before clamping onto a conductor 4 Place the meter so...

Страница 13: ...amp and the number of dashes displayed If the meter does not emit a tone or flash the LED in this mode there is still the possibility that voltage is present please use caution 1 Turn the function swi...

Страница 14: ...e in the display The display will indicate the proper decimal point and value If the reading is out of range the OL display icon will appear Fig 4 5 RESISTANCE MEASUREMENTS Resistance Measurement Note...

Страница 15: ...or circuit under test 5 If the resistance is 10 the beeper will sound continuously If the resistance is between 10 and 100 the beeper may or may not sound For an open circuit condition the meter will...

Страница 16: ...ve mode to remove test lead and probe capacitance 6 Read the capacitance value in the display 7 The display will indicate the proper decimal point and value Fig 4 7 CAPACITANCE MEASUREMENTS Capacitanc...

Страница 17: ...h the test probe tips to the diode or semiconductor junction under test Note the meter reading 4 Reverse the test lead polarity by reversing the red and black leads Note this reading 5 The diode or ju...

Страница 18: ...r more remove the battery and store separately Do not mix battery types or freshness levels please use batteries of the same type and of the same freshness level Never dispose of used batteries or rec...

Страница 19: ...00 0V 0 1V 750V 1V 1 5 5 digits True RMS voltage applicable to 10 100 of the range Input Impedance 10M Frequency response 40 400Hz DC Voltage 6 000V 0 001V 0 8 3 digits 1000V DC 750V AC 60 00V 0 01V 6...

Страница 20: ...tance 60 00nF 0 01nF 4 0 20 digits 1000V DC 750V AC 600 0nF 0 1nF 6 000 F 0 001 F 60 00 F 0 01 F 600 0 F 0 1 F 6 000mF 0 001mF 10 60 00mF 0 01mF For reference only Non Contact Voltage Detector NCV 100...

Страница 21: ...ower OFF After 15 minutes Operating Temperature and Humidity 0 30 C 32 86 F 80 RH maximum 30 40 C 86 104 F 75 RH maximum 40 50 C 104 122 F 45 RH maximum Storage Temperature and Humidity 20 60 C 4 140...

Отзывы: