USER

 

GUIDE

 

 

 

 

True

 

RMS

 

300A

 

AC/DC

 

Mini

 

Clamp

 

Meter

 

with

 

Non

Contact

 

Voltage

 

Detector

 

 

Model

 

MA145

 

 

  
 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание MA145

Страница 1: ...USER GUIDE True RMS 300A AC DC Mini Clamp Meter with Non Contact Voltage Detector Model MA145 www GlobalTestSupply com nd Quality Products Online at sales GlobalTestSupply co...

Страница 2: ...protective equipment should be used if HAZARDOUS LIVE parts in the installation where measurements are to be carried out could be accessible If the equipment is used in a manner not specified by the m...

Страница 3: ...f OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which measures are taken to limit the transient over voltages to an appropriate low level Note Examples include protected electronic...

Страница 4: ...rement 8 Amperes current 9 Main Display area 10 Battery status icon 11 Minus negative sign 12 Non Contact Volt Detect icons Control Button Description Press for 2 seconds to access In rush Current mod...

Страница 5: ...ote The meter displays the battery capacity when powering up Disable Auto Power OFF The meter will auto power OFF after 20 minutes of inactivity To defeat this feature follow the steps below 1 With th...

Страница 6: ...ton to toggle DC and AC 3 When in AUTO mode the display shows the AUTO icon in the upper left corner 4 The meter display will show AC or DC on the right side of the display 5 When in DC Current mode p...

Страница 7: ...4 To exit the Inrush Current mode press the INRUSH button again momentarily The INRUSH icon will switch OFF TIME CURRENT 0A Start Stop Current Detection Threshold Measured Inrush Current 100ms Sample...

Страница 8: ...ct Voltage Detect mode 2 Note the voltage detection display icons as shown in the Description section of this guide 3 Place the meter near a source of electrical energy The tip of the clamp offers the...

Страница 9: ...rect polarity 4 Re assemble the meter before use 5 Safety Please dispose of batteries responsibly never dispose of batteries in a fire batteries may explode or leak never mix battery types install new...

Страница 10: ...aracteristic 24db per octave approximately Function Range Resolution Accuracy of reading Inrush Current 300 0 A 0 1 3 5 5 digits Integration time 100ms Trigger current threshold 5A Voltage Detector 80...

Страница 11: ...accuracy C 18 C 64 5 F 28 C 82 4 F Operating Altitude 2000m 6562ft Battery power 2 LR 44 1 5V batteries battery life 20 hours typical Weight 140g 4 9 oz Dimensions 60 x 147 x 31 5mm 2 4 x 5 8 x 1 2 S...