background image

LT505-en-GB_V1.1   1/18 

Specifications 

 

 

 

 

Display 

9999 count LCD  

Sampling rate 2.5 times per second 

Light sensor 

Silicone photodiode with cosine correction filter 

Measurement Units 

LUX and FC (Foot candles) 

Lighting source types 

Fluorescent, metal halide, high-pressure sodium, and 
incandescent 

Input Overload Display 

‘OL’ 

Tripod mount 

On back of meter 

Power 

2 x 1.5V AAA batteries 

Low battery indicator included 

Automatic power off 

After approx. 12 minutes of inactivity 

Operating Temp/Humidity 

5°C to 40°C (40°F to 104°F); <80%RH Max 

Operating Altitude 

2000 meters (7000ft) maximum 

Storage Temp/Humidity 

-10°C to 60°C (14°F to 140°F); <70%RH Max 

Dimensions/Weight 

133 x 48 x 23mm (5.3 x 1.9 x 0.9”) /250g (8.8oz) 

Safety 

For indoor use only. EMC: EN61326-1 (2006), IEC 61000-
4-2 (2008, IEC 61000-4-3 (2006) + (2007); Pollution 
Degree 2. 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание LT505

Страница 1: ...USER MANUAL LUX FC Light Meter Model LT505 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...entire User Manual before operating this device Use the meter only as specified and do not attempt to service or open the meter housing Do not use the meter in the presence of explosive gas or vapor D...

Страница 3: ...appear in the secondary display 4 The CAL icon will switch OFF when the calibration has been completed 5 If the protective cap is not covering the sensor when the button is pressed the LCD display wil...

Страница 4: ...press the button The MAX AVG MIN display icons will switch off and the meter will return to normal operating mode Auto Power OFF APO In order to conserve battery life the meter will automatically shut...

Страница 5: ...ve the battery and store separately Never dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collectio...

Страница 6: ...ter Power 2 x 1 5V AAA batteries Low battery indicator included Automatic power off After approx 12 minutes of inactivity Operating Temp Humidity 5 C to 40 C 40 F to 104 F 80 RH Max Operating Altitude...

Страница 7: ...tions 23 5 C Lux autorange Unit Range Resolution Accuracy Lux 999 9 0 1 3 rdg 3 dgts 9 999 1 3 rdg 10 dgts 99 990 10 400 000 100 Foot candle autorange Unit Range Resolution Accuracy fc 99 99 0 01 3 rd...

Страница 8: ...om Dining Table 750 1 500 75 150 Clerical Work 750 1 500 75 150 Show Window 1 500 2 000 150 2000 Typing Drafting Store Hospital 75 150 7 15 Indoors 30 75 3 7 Emergency Stairs 150 200 15 20 Corridor St...