background image

LT45-EU-EN v1.4   9/13 

7

Measurement

 

Considerations

 

and

 

User

 

Tips

 

For

 

maximum

 

accuracy

 

allow

 

the

 

light

 

being

 

measured

 

to

 

fall

 

directly

 

on

 

the

 

sensor

 

as

 

perpendicular

 

as

 

possible

 

with

 

a

 

minimal

 

angle

 

of

 

incidence.

When

 

the

 

meter

 

is

 

not

 

in

 

use,

 

please

 

keep

 

the

 

protective

 

cap

 

in

 

place,

 

covering

 

the

 

light

sensor.

 

This

 

will

 

prolong

 

the

 

life

 

of

 

the

 

sensor.

When

 

the

 

meter

 

is

 

to

 

be

 

stored

 

for

 

long

 

periods,

 

please

 

remove

 

the

 

battery

 

and

 

store

 

it

separately.

 

Batteries

 

can

 

leak

 

and

 

cause

 

damage

 

to

 

the

 

meter’s

 

components.

Avoid

 

areas

 

of

 

high

 

temperature

 

and

 

humidity

 

when

 

using

 

this

 

instrument.

Battery

 

Replacement

 

and

 

Maintenance

 

Cleaning

 

and

 

storage

 

1. The

 

white

 

plastic

 

sensor

 

dome

 

should

 

be

 

cleaned

 

with

 

a

 

damp

 

cloth

 

when

 

necessary.

 

Use

only

 

a

 

mild

 

soap

 

if

 

needed.

 

Do

 

not

 

use

 

solvents,

 

abrasives,

 

or

 

harsh

 

detergents

 

to

 

clean

 

the

dome.

2. Store

 

the

 

meter

 

in

 

an

 

area

 

with

 

moderate

 

temperature

 

and

 

relative

 

humidity.

Battery

 

Replacement

 

When

 

the

 

battery

 

power

 

decreases

 

to

 

a

 

critical

 

level,

 

the

 

battery

 

symbol

 

will

 

appear

 

as

 

empty

 

on

 

the

 

LCD.

 

Replace

 

the

 

9V

 

battery

 

located

 

in

 

the

 

rear

 

battery

 

compartment.

 

The

 

battery

 

compartment

 

slides

 

easily

 

downward

 

for

 

removal

 

(in

 

the

 

direction

 

of

 

the

 

printed

 

arrow

 

on

 

the

 

rear

 

of

 

the

 

meter).

 

Ensure

 

that

 

the

 

compartment

 

cover

 

is

 

securely

 

fastened

 

before

 

using

 

the

 

meter.

 

Never

 

dispose

 

of

 

used

 

batteries

 

or

 

rechargeable

 

batteries

 

in

 

household

 

waste.

 

As

 

consumers,

 

users

 

are

 

legally

 

required

 

to

 

take

 

used

 

batteries

 

to

 

appropriate

 

collection

 

sites,

 

the

 

retail

 

store

 

where

 

the

 

batteries

 

were

 

purchased,

 

or

 

wherever

 

batteries

 

are

 

sold.

 

Disposal:

 

Do

 

not

 

dispose

 

of

 

this

 

instrument

 

in

 

household

 

waste.

 

The

 

user

 

is

 

obligated

 

to

 

take

 

end

of

life

 

devices

 

to

 

a

 

designated

 

collection

 

point

 

for

 

the

 

disposal

 

of

 

electrical

 

and

 

electronic

 

equipment.

  

Battery

 

Safety

 

Reminders

 

o

Please

 

dispose

 

of

 

batteries

 

responsibly;

 

observe

 

local,

 

state,

 

national

 

regulations.

o

Never

 

dispose

 

of

 

batteries

 

in

 

a

 

fire;

 

batteries

 

may

 

explode

 

or

 

leak.

netzerotools.com

netzerotools.com

Содержание LT40

Страница 1: ...USER GUIDE LED Light Meter Model LT45 netzerotools com netzerotools com netzerotools com Extech LT40 LED Light Meter Extech LT45 Color LED Light Meter ...

Страница 2: ...se will provide years of reliable service Please visit our website to check for the latest version of this User Guide Product Updates and Customer Support Features Overload Indication LCD screen will show OL at the upper left hand corner Battery strength status indication Display Update Rate 2 5 times per second Spectral response near CIE luminous spectral efficiency ratings Cosine Angle corrected...

Страница 3: ...e the sensitive components For Indoor use only This instrument was designed for pollution degree 2 Operation Altitude Up to 2000m 7000 Meter Description 1 Display LCD 2 Lux Fc CD unit select button 3 MEM READ button for 99 reading memory 4 Up arrow button and MAX MIN AVG button 5 Power and Auto Power OFF control button 6 Zero Calibration button 7 Data Hold and Light source select button 8 Down arr...

Страница 4: ...rger digits e g 399900 LUX FC CD Units Momentary presses of the LUX FC CD button toggles Lux and FC foot candles units Press and hold the button to enter the CD luminous intensity mode Refer to Luminous Intensity section for further information Auto Power OFF To save battery life the meter powers down automatically after approximately 5 minutes of inactivity no button presses Enable Disable Auto P...

Страница 5: ...readings can be stored 2 To review read the stored readings press and hold the Mem Read button until the MEM icon appears at the top of the LCD Now use the arrow buttons to scroll through the stored readings The small M icon and the memory location counter 1 to 99 will be shown on the lower left hand corner of the LCD while the main display digits show the stored reading for the selected memory lo...

Страница 6: ...ce selections L0 L9 each having a unique calibration correction factor multiplier See the Light Source Factors list below The multipliers for locations L0 through L6 are fixed for the lighting types listed Locations L7 through L9 are extra locations that the user can customize with a multiplier from 0 001 to 1 999 To change the light source L S selection 1 Press and hold the Hold LS button for 2 s...

Страница 7: ...nd relative humidity Battery Replacement When the battery power decreases to a critical level the battery symbol will appear as empty on the LCD Replace the 9V battery located in the rear battery compartment The battery compartment slides easily downward for removal in the direction of the printed arrow on the rear of the meter Ensure that the compartment cover is securely fastened before using th...

Страница 8: ...incandescent lamp 2856 o K at an ambient temperature of 23 o C 6 for other visible light sources 30 2 60 6 Angle deviation from cosine characteristics 80 25 LED Types Meter measures white red yellow green blue purple LED light Operating conditions Temperature 5 to 40 o C 41 to 104 o F Humidity 80 RH Storage Temperature RH 10 to 60 o C 14 to 140 o F Humidity 70 RH Battery status indication Battery ...

Страница 9: ...00 10 20 Corridor Stairs 150 300 15 30 Entrance Wash Room 200 750 20 75 Conference Reception Room 300 750 30 75 Cooking Room Dining Table 750 1 500 75 150 Clerical Work 750 1 500 75 150 Show Window 1 500 2 000 150 2000 Typing Drafting Store Hospital 75 150 7 15 Indoors 30 75 3 7 Emergency Stairs 150 200 15 20 Corridor Stairs 75 100 7 10 Stairs 200 300 20 30 Reception 100 150 10 15 Sick Room Wareho...

Отзывы: