background image

EXTECH

 

INSTRUMENTS

 

4

                                                     

IR260

en

GB_V1.2

   

1/16

 

Operation

 

Meter

 

Power

 

The

 

meter

 

is

 

powered

 

by

 

two

 

1.5V

 

AA

 

batteries.

 

With

 

fresh

 

batteries

 

installed,

 

the

 

meter

 

switches

 

ON

 

when

 

the

 

trigger

 

is

 

pulled.

 

The

 

batteries

 

are

 

located

 

in

 

the

 

meter

 

handle;

 

pull

 

the

 

battery

 

compartment

 

lid

 

away

 

from

 

the

 

body

 

of

 

the

 

meter

 

to

 

open.

 

Refer

 

to

 

the

 

Maintenance

 

section

 

for

 

more

 

Battery

 

Installation

 

instructions.

 

The

 

battery

 

icon

 

provides

 

battery

 

status

 

indication.

 

Replace

 

the

 

batteries

 

as

 

soon

 

as

 

the

 

battery

 

status

 

icon

 

flashes.

 

Surface

 

Temperature

 

Measurements

 

1.

 

Hold

 

the

 

meter

 

by

 

its

 

Handle

 

Grip

 

and

 

point

 

it

 

toward

 

the

 

surface

 

to

 

be

 

measured.

 

Read

 

the

 

Field

 

of

 

View

 

section

 

below

 

for

 

distance

 

to

 

target

 

(spot)

 

ratio

 

information.

 

2.

 

Pull

 

and

 

hold

 

the

 

Trigger

 

to

 

turn

 

the

 

meter

 

on

 

and

 

begin

 

testing

 

in

 

Scan

 

mode.

 

The

 

display

 

will

 

light

 

if

 

the

 

two

 

1.5V

 

batteries

 

are

 

good.

 

Replace

 

the

 

batteries

 

if

 

the

 

display

 

does

 

not

 

light.

 

3.

 

Release

 

the

 

Trigger;

 

the

 

reading

 

will

 

hold

 

for

 

approximately

 

9

 

seconds,

 

after

 

which

 

the

 

meter

 

will

 

automatically

 

shut

 

off.

 

4.

 

The

 

meter

 

defaults

 

to

 

the

 

programmed

 

conditions

 

in

 

use

 

when

 

the

 

meter

 

was

 

last

 

switched

 

OFF.

 

For

 

example,

 

if

 

the

 

laser

 

is

 

set

 

to

 

ON

 

and

 

the

 

temperature

 

units

 

are

 

set

 

to

 

o

F

 

at

 

the

 

time

 

the

 

unit

 

is

 

switched

 

OFF,

 

the

 

unit

 

will

 

switch

 

ON

 

and

 

use

 

the

 

same

 

settings.

 

Laser

 

 

ON/OFF

 

Pull the trigger and release. 

Push

 

and

 

HOLD

 

the

 

 

button

 

for

 

about

 

3

 

seconds

 

to

 

switch

 

the

 

laser

 

pointer

 

ON

 

or

 

OFF.

   

The

 

Laser

 

icon

 

will

 

flash

 

when

 

the

 

state

 

has

 

changed.

 

When

 

the

 

laser

 

is

 

ON,

 

the

 

laser

 

icon

will

 

appear

 

on

 

the

 

LCD.

 

Aim

 

the

 

red

 

laser

 

beam

 

approximately

 

a

 

half

 

inch

 

below

 

the

 

point

 

of

 

test

 

(pressing

 

the

 

Laser

 

button

 

again

 

turns

 

the

 

laser

 

off).

 

MAX

MIN

 

Mode

 

Press

 

the

 

trigger

 

and

 

release.

 

Press

 

the

 

MAX

MIN

 

button

 

to

 

view

 

the

 

maximum

 

temperature

 

reading

 

(MAX),

 

press

 

again

 

to

 

view

 

the

 

lowest

 

reading

 

(MIN).

 

Press

 

and

 

hold

 

the

 

MAX

MIN

 

button

 

to

 

switch

 

the

 

MAX

MIN

 

mode

 

off.

 

Display

 

Backlight

 

Press

 

the

 

trigger

 

and

 

release.

 

Press

 

the

 

backlight

 

button

 

momentarily

 

to

 

switch

 

the

 

backlight

 

ON

 

or

 

OFF.

  

Over

range

 

Indicators

 

(OL

 

and

 ‐

OL)

 

If

 

the

 

temperature

 

measurement

 

exceeds

 

779°F

 

(415°C),

 

the

 

thermometer

 

will

 

display

 

OL

 

in

 

place

 

of

 

a

 

temperature

 

reading.

 

If

 

the

 

temperature

 

measurement

 

is

 

below

  ‐

25°C

 

(

13°F),

 

the

 

thermometer

 

will

 

display

 ‐

OL

 

in

 

place

 

of

 

a

 

temperature

 

reading.

 

 

Содержание IR260

Страница 1: ...USER GUIDE Mini InfraRed Thermometer With Laser Pointer and High Low Alarms Model IR260...

Страница 2: ...and visible alarm indication for High and Low Temperature Alarm Safety International Safety Symbols This symbol adjacent to another symbol or terminal indicates the user must refer to the manual for...

Страница 3: ...Description Emissivity value indication Laser pointer active icon Scan mode active while the trigger is pulled displayed temperature tracks the temperature of the scanned surfaces Hold mode displayed...

Страница 4: ...eter defaults to the programmed conditions in use when the meter was last switched OFF For example if the laser is set to ON and the temperature units are set to o F at the time the unit is switched O...

Страница 5: ...meter is used to enable disable the audible temperature alarm The icon will flash in this mode Use the up and MAX MIN down buttons to toggle the setting When the audible alarm is disabled the display...

Страница 6: ...surement may be affected by external sources of light In addition the spot size may be so large that it encompasses surface areas not intended to be measured It is necessary to ensure that the size of...

Страница 7: ...ot aim the meter outside the area of interest then scan across in an up and down motion until the hot spot is located Maintenance Cleaning To clean the lenses use compressed air to clear dust and othe...

Страница 8: ...es in a fire batteries may explode or leak If the meter is not to be used for 60 days or more remove the battery and store separately Do not mix battery types or freshness levels please use batteries...

Страница 9: ...istance to Spot ratio Laser power Less than 1mW Spectral response 630 to 670 nm wavelength General Specifications Display Backlit LCD display with function indicators Display rate 500ms approx Operati...

Отзывы: