background image

EXTECH

 

INSTRUMENTS

 

2

                                               

IR255

en

EU_V1.4

   

9/14

 

Introduction

 

Congratulations

 

on

 

your

 

purchase

 

of

 

the

 

IR255

 

IR

 

Thermometer.

 

This

 

thermometer

 

makes

 

non

contact

 

(infrared)

 

temperature

 

measurements

 

at

 

the

 

touch

 

of

 

a

 

button.

 

The

 

built

in

 

laser

 

pointer

 

increases

 

target

 

accuracy

 

while

 

the

 

backlit

 

LCD

 

and

 

handy

 

push

buttons

 

combine

 

for

 

convenient,

 

ergonomic

 

operation.

 

This

 

device

 

is

 

shipped

 

fully

 

tested

 

and

 

calibrated

 

and,

 

with

 

proper

 

use,

 

will

 

provide

 

years

 

of

 

reliable

 

service.

 

Please

 

visit

 

our

 

website

 

(www.extech.com)

 

to

 

check

 

for

 

the

 

latest

 

version

 

of

 

this

 

User

 

Guide,

 

Product

 

Updates,

 

and

 

Customer

 

Support.

 

Features

 

 

Measures

 

non

contact

 

surface

 

temperature

 

up

 

to

 

400°C

 

(752°F)

 

 

12:1

 

Distance

 

to

 

Spot

 

Ratio

 

(Field

 

of

 

View)

 

 

Single

point

 

laser

 

targeting

 

 

Automatic

 

Data

 

Hold

 

when

 

trigger

 

is

 

released

 

 

Display

 

Backlight

 

 

Maximum

Minimum

 

temperature

 

function

 

 

Selectable

 

temperature

 

units

 

(°C

 

/

 

°F)

 

 

Dynamic

 

battery

 

status

 

indication

 

 

Adjustable

 

emissivity

 

 

Audible

 

and

 

visible

 

alarm

 

indication

 

for

 

High

 

and

 

Low

 

Temperature

 

Alarm

 

Safety

 

International

 

Safety

 

Symbols

 

This

 

symbol,

 

adjacent

 

to

 

another

 

symbol

 

or

 

terminal,

 

indicates

 

the

 

user

 

must

 

refer

 

to

 

the

 

manual

 

for

 

further

 

information

 

Warnings

 

o

 

Do

 

not

 

directly

 

or

 

indirectly

 

point

 

the

 

laser

 

at

 

the

 

eyes

 

of

 

a

 

person

 

or

 

an

 

animal

 

o

 

Inspect

 

for

 

damage

 

or

 

for

 

any

 

shortage

 

of

 

parts

 

or

 

accessories

 

before

 

use

 

o

 

Replace

 

the

 

battery

 

immediately

 

after

 

the

 

battery

 

indicator

 

flashes

 

o

 

Do

 

not

 

use

 

the

 

thermometer

 

near

 

explosive

 

gases,

 

steam,

 

or

 

dust

 

o

 

Note

 

that

 

an

 

object

 

with

 

high

 

reflectivity

 

will

 

normally

 

cause

 

the

 

measured

 

temperature

 

value

 

to

 

read

 

much

 

lower

 

than

 

the

 

actual

 

temperature

 

o

 

Use

 

the

 

device

 

only

 

as

 

described

 

in

 

this

 

User

 

Guide

 

Cautions

 

To

 

avoid

 

thermometer

 

damage,

 

please

 

avoid

 

the

 

following

 

hazards:

 

o

 

EMF

 

from

 

welding

 

equipment

 

or

 

electro

induction

 

heaters

 

o

 

Static

 

electricity

 

o

 

Thermal

 

shock

 

caused

 

by

 

large

 

or

 

abrupt

 

environmental

 

temperature

 

changes;

 

wait

 

30

 

minutes

 

to

 

allow

 

the

 

thermometer

 

to

 

stabilize

 

to

 

new

 

environmental

 

conditions

 

o

 

Do

 

not

 

use

 

this

 

device

 

in

 

excessively

 

high

 

temperature

 

environments

  

 

Содержание IR255

Страница 1: ...USER GUIDE Mini InfraRed Thermometer With Laser Pointer and High Low Alarms Model IR255...

Страница 2: ...ity Audible and visible alarm indication for High and Low Temperature Alarm Safety International Safety Symbols This symbol adjacent to another symbol or terminal indicates the user must refer to the...

Страница 3: ...splay Description Emissivity value indication Laser pointer active icon Scan mode active while the trigger is pulled displayed temperature tracks the temperature of the scanned surfaces Hold mode disp...

Страница 4: ...laser beam approximately a half inch below the point of test pressing the Laser button again turns the laser off b Select the temperature units o C o F in the Settings Mode see later section c Push t...

Страница 5: ...eter is used to enable disable the audible temperature alarm The icon will flash in this mode Use the up and down buttons to toggle the setting When the audible alarm is disabled the display will show...

Страница 6: ...ment may be affected by external sources of light In addition the spot size may be so large that it encompasses surface areas not intended to be measured It is necessary to ensure that the size of the...

Страница 7: ...spot aim the meter outside the area of interest then scan across in an up and down motion until the hot spot is located Maintenance Cleaning To clean the lenses use compressed air to clear dust and o...

Страница 8: ...y if the device is to be stored for longer than 60 days o Never dispose of batteries in a fire Batteries may explode or leak o Never mix battery types Always install new batteries of the same type Nev...

Страница 9: ...D distance S spot Laser power Less than 1mW Spectral response 630 to 670 nm wavelength General Specifications Display 1999 count backlit LCD display with function indicators Display rate 250ms approx...

Отзывы: