Extech Instruments HD300 Скачать руководство пользователя страница 3

HD300-EU-EN V2.2   07/13 

Meter Description 

1. 

LED display

 for Air Velocity, Air Flow, Probe 

Temperature, and remote surface temperature. Units 
of measurement and user alerts are also displayed on 
the LCD. 

2. 

Vane Sensor

. Hold the sensor in the flow of air to take 

a reading. 

3. 

IR sensor: 

Non-contact temperature measurement for 

remote surfaces. 

4. 

Laser Pointer: 

Helps the user aim the IR sensor. 

5. 

Battery access: 

Cover on rear panel 

6. 

PC interface jack: 

Use the supplied cable to connect 

meter to a PC 

7. 

Upper Keypad

 (brief descriptions below): 

 

IRT: 

Press and hold to measure remote surface temperature. Release to hold the 

temperature value on the display.

 

 

MAX/MIN (for air temperature measurements)

: Used to record and store the highest 

and lowest readings for temperature measurements made by the vane probe. 

 

AVG

: Used to obtain Average for multi-point measurements in either FLOW or 

VELOCITY modes. Up to twenty (20) points can be averaged. 

 

HOLD 

 (for air temperature measurements): 

Press to freeze the displayed 

temperature reading measured by the probe. Press again to unlock the display. Press 
and hold for 2 seconds to activate the LCD backlight. Press and hold again for 2 
seconds to turn the backlight off. 

8. 

Lower Keypad

 

 

On/Off button 

: Press to turn the meter ON or OFF 

 

MAX/MIN   (for air velocity and air flow)

: Press to record and store the highest, 

lowest and continuous moving average readings for single point measurements. This 
button also functions as the decimal positioning tool in the AREA mode. 

 

C-F UNITS

: Press to select the mode of operation and unit of measure. In FLOW 

mode, the meter displays air volume. In VELOCITY mode, the meter displays air speed. 
This button also functions as the UP arrow button in AREA mode. 

 

AREA / NEXT

: Press and hold to enter the AREA mode. The NEXT function allows the 

user to save AREA values to any of eight memory locations. This button is also used to 
clear stored readings in the MAX/MIN/AVG modes. 

 

HOLD   (for air velocity and air flow measurements) Backlight:

 Press to freeze the 

displayed air velocity or air flow reading. Press again to unlock display. This button also 
functions as the right arrow button in the AREA mode. 

NOTE

: Battery Compartment and Tripod Mount are located on the reverse side of the meter 

1

2

5

7

6

4

3

8

Содержание HD300

Страница 1: ...USER GUIDE Heavy Duty CFM CMM Thermo Anemometer With built in non contact IR Thermometer and Laser Pointer Model HD300 ...

Страница 2: ...a 30 1 distance to spot ratio and Laser pointer Simultaneous display of Air Flow or Air Velocity plus ambient temperature Eight 8 memory locations permit the user to store multiple air duct AREA values for fast and easy recall Twenty 20 reading average for Air Flow or Air Velocity Large backlit LCD display 3 velocity accuracy via low friction 72mm 2 83 ball bearing vane wheel on a 120cm 3 9 cable ...

Страница 3: ...d by the probe Press again to unlock the display Press and hold for 2 seconds to activate the LCD backlight Press and hold again for 2 seconds to turn the backlight off 8 Lower Keypad On Off button Press to turn the meter ON or OFF MAX MIN for air velocity and air flow Press to record and store the highest lowest and continuous moving average readings for single point measurements This button also...

Страница 4: ...ic meters per minute as desired 4 Measure the dimensions of the duct or vent in question and calculate the area in square feet or square meters Note If the dimensional measurements are made in inches or cm convert them feet or meters before calculating the square area 5 To begin entering the area in m 2 or ft 2 press and hold the AREA button for approx 2 seconds until two tones are heard 6 Momenta...

Страница 5: ...ed is the temperature of the area within the spot 6 When the IRT button is released the laser pointer will switch off and the reading will freeze data hold on the display for approximately 7 seconds 7 After the 7 second hold time the meter returns to the Air Velocity Flow and Air Temperature mode WARNING Do not directly view or direct the laser pointer at an eye Low power visible lasers do not nor...

Страница 6: ...o view the MIN value display will show REC MIN Now the display will show only the lowest reading 5 Press again to view the AVG value display will show REC AVG 6 To return to normal operation mode press and hold the MAX MIN button until two tones are heard Multi point Average In the Multi Point Average Mode the meter averages up to 20 Air Velocity readings 1 Turn the meter ON 2 Press and hold the A...

Страница 7: ...rride The HD300 is programmed to turn off automatically after idling for 15 minutes This is designed to save battery life in the event the meter is left ON inadvertently Note When the meter is in the CFF CMM or Average mode Auto Power Off is disabled To over ride this feature 1 Turn the meter OFF 2 Turn the meter ON while holding down the IRT button 3 Release the button when appears in the display...

Страница 8: ...lat black paint before measuring Steam dust smoke etc can obstruct measurements To find a hot spot aim the meter outside the area of interest then scan across in an up and down motion until the hot spot is located IR measurements cannot be made through glass IR Field of View Ensure that the desired target is larger than the spot size As the distance from an object increases the spot size of the ar...

Страница 9: ...0 75 to 0 80 Sand 0 90 Charcoal powder 0 96 Earth 0 92 to 0 96 Lacquer 0 80 to 0 95 Water 0 67 Lacquer matt 0 97 Ice 0 96 to 0 98 Rubber black 0 94 Snow 0 83 Plastic 0 85 to 0 95 Glass 0 85 to 1 00 Timber 0 90 Ceramic 0 90 to 0 94 Paper 0 70 to 0 94 Marble 0 94 Chromium oxides 0 81 Plaster 0 80 to 0 90 Copper Oxides 0 78 Mortar 0 89 to 0 91 Iron Oxides 0 78 to 0 82 Brick 0 93 to 0 96 Textiles 0 90...

Страница 10: ... above formulae Unit of Measure Conversion Table m s ft min knots km h MPH 1 m s 1 196 87 1 944 3 6 2 24 1 ft min 0 00508 1 0 00987 0 01829 0 01138 1 knot 0 5144 101 27 1 1 8519 1 1523 1 km h 0 2778 54 69 0 54 1 0 6222 1 MPH 0 4464 87 89 0 8679 1 6071 1 Width W Height H Area A Width W x Height H CFM ft 3 min Air Velocity ft min x Area ft 2 CMM m 3 min Air Velocity m sec x Area m 2 x 60 Radius Area...

Страница 11: ...ilt into the vane assembly Surface temperature via non contact IR sensor IR Distance to Spot ratio 30 1 IR Spectral response 6 to 14µm IR Emissivity 0 95 fixed MIN MAX AVG Record and Recall lowest highest and average readings Auto Power OFF Automatic shut off after 15 minutes can be disengaged PC Interface USB PC Communication with supplied software and cable for data acquisition Over range indica...

Страница 12: ...knots 3 0 4knots Air Flow Measurements Range Resolution Area CMM cubic meters per minute 0 999 900 m 3 min 0 001 0 to 999 9m 2 CFM cubic feet per minute 0 999 900 ft 3 min 0 001 0 to 999 9ft 2 Temperature Range Resolution Accuracy Air Temperature vane 10 to 60 o C 14 to 140 o F 0 1 o C F 2 o C 4 o F 50 to 20 o C 58 to 4 o F 0 1 o C F 5 o C 9 o F Surface Temperature IR 20 to 500 o C 4 to 932 o F 0 ...

Отзывы: