background image

 

4                                          EZ40-en-US_v1.4   10/21 

Maintenance 

Caution!   

Storing in a damp environment will damage the sensor!

 

Battery Replacement 

If the green READY LED flashes or does not illuminate, the batteries need to be 
replaced. The battery compartment is located at the rear of the EZ40. Replace the 
three “C” batteries by sliding the battery compartment door and accessing the battery 
compartment.  Ensure that the compartment cover is securely fastened when finished. 

 

Safety: Please dispose of batteries responsibly; never dispose of batteries in a fire, 
batteries may explode or leak. If the meter is not to be used for 60 days or more, 
remove the battery and store separately. 

 

Cleaning and Storage 

Wipe the meter only with a damp cloth as needed. Do not apply abrasive, solvents, or other 
cleaners to the surface of the meter or sensor. Store with the batteries removed and avoid extreme 
temperature and humidity. 

Specifications 

Gases Detected 

Natural Gas, Methane, Ethane, Propane, Butane, Acetone, Alcohol, 
Ammonia, Gasoline, Jet Fuel, Hydrogen Sulfide, Smoke, Industrial 
Solvents, Lacquer Thinner, Naphtha, Steam 
Carbon Monoxide (indication only, not to quantify), 

Sensitivity

 

50 ppm methane

 

Sensor 

Solid State (Metal Oxide)

 

Alarm

 

Visual and Audible at minimum 10% LEL (40% max) for Methane

 

Warm-up

 

Approx. 5 minute

 

Response Time

 

Less than 2 seconds (up to 40% LEL)

 

Duty Cycle 

Intermittent 

Power supply

 

3 x “C” 1.5V alkaline batteries

 

Battery life

 

Approx. 8 hours continuous use typical

 

Operating Temperature

 

32 to 122

o

F (0 to 50

o

C)

 

Storage Temperature

 

-22 to 140

o

F (-30 to 60

o

C)

 

Operating Humidity

 

10 to 90% RH (non condensing)

 

Approvals 

CE 

Dimensions

 

8.7 x 2.83 x 1.8” (221 x 72 x 46mm); gooseneck 16” (40cm)

 

Weight

 

18.4oz (520g)

 

 

 

Содержание EzFlex EZ40

Страница 1: ...User Manual EzFlex Combustible Gas Leak Detector Model EZ40 ...

Страница 2: ... Lacquer Thinner Naphtha in concentrations as low as 10 LEL for Methane and alerts the user with audible and visual alarms The 16 406mm flexible gooseneck provides easy access in difficult to reach locations This meter is shipped fully tested and calibrated and with proper use will provide years of reliable service Description 1 Probe clip 2 Sensor tip guard sensor 3 Alarm light 4 Ready light Powe...

Страница 3: ...evel and decrease to zero Earphone Jack In an area with high levels of background noise an earphone can be plugged in to the EZ40 In addition the speaker is disabled when an earphone is connected so the ticking and alarm will not disturb others in the general area Caution Tick and alarm sounds through the earphone are very loud LEL a definition The LEL of a flammable gas is the minimum concentrati...

Страница 4: ...ly abrasive solvents or other cleaners to the surface of the meter or sensor Store with the batteries removed and avoid extreme temperature and humidity Specifications Gases Detected Natural Gas Methane Ethane Propane Butane Acetone Alcohol Ammonia Gasoline Jet Fuel Hydrogen Sulfide Smoke Industrial Solvents Lacquer Thinner Naphtha Steam Carbon Monoxide indication only not to quantify Sensitivity ...

Страница 5: ...libration for most of our products Contact us for information on calibration and repair availability refer to the contact information below Annual calibrations should be performed to verify meter performance and accuracy Product specifications are subject to change without notice Please visit our website for the most up to date product information www extech com Contact Customer Support Customer S...

Отзывы: