Data

 

Hold

 

To

 

freeze

 

the

 

LCD

 

reading,

 

press

 

the

 

HOLD

 

button.

 

While

 

data

 

hold

 

is

 

active,

 

the

 

HOLD

 

icon

 

appears

 

on

 

the

 

LCD.

 

Press

 

the

 

HOLD

 

button

 

again

 

to

 

return

 

to

 

normal

 

operation.

 

Peak

 

Hold

  

The

 

Peak

 

Hold

 

function

 

captures

 

the

 

peak

 

AC

 

or

 

DC

 

voltage

 

or

 

current.

 

The

 

meter

 

can

 

capture

 

negative

 

or

 

positive

 

peaks

 

as

 

fast

 

as

 

1

 

millisecond

 

in

 

duration.

  

1.

 

Turn

 

the

 

function

 

switch

 

to

 

the

 

A

 

or

 

V

 

position.

 

2.

 

Use

 

the

 

MODE

 

button

 

to

 

select

 

AC

 

or

 

DC

  

3.

 

Allow

 

time

 

for

 

the

 

display

 

to

 

stabilize.

 

4.

 

Press

 

and

 

Hold

 

the

 

PEAK

 

button

 

until

 

CAL

 

appears

 

in

 

the

 

display.

 

This

 

procedure

 

will

 

zero

 

the

 

range

 

selected.

 

5.

 

Press

 

the

 

PEAK

 

button,

 

Pmax

 

will

 

display.

 

6.

 

The

 

display

 

will

 

update

 

each

 

time

 

a

 

higher

 

positive

 

peak

 

occurs.

 

7.

 

Press

 

the

 

PEAK

 

button

 

again,

 

Pmin

 

will

 

display.

 

The

 

display

 

will

 

now

 

update

 

and

 

indicate

 

the

 

lowest

 

negative

 

peak.

 

8.

 

To

 

return

 

to

 

normal

 

operation,

 

press

 

and

 

hold

 

the

 

PEAK

 

button

 

until

 

the

 

Pmin

 

or

 

Pmax

 

indicator

 

switches

 

off.

 

Note

:

 

If

 

the

 

Function

 

switch

 

position

 

is

 

changed

 

after

 

a

 

calibration

 

the

 

Peak

 

Hold

 

calibration

 

must

 

be

 

repeated

 

for

 

the

 

new

 

function

 

selected.

 

MAX/MIN

  

1.

 

Press

 

the

 

MAX/MIN

 

key

 

to

 

activate

 

the

 

MAX/MIN

 

recording

 

mode.

 

The

 

display

 

icon

 

"

MAX

"

 

will

 

appear.

 

The

 

meter

 

will

 

display

 

and

 

hold

 

the

 

maximum

 

reading

 

and

 

will

 

update

 

only

 

when

 

a

 

new

 

“max”

 

occurs.

 

2.

 

Press

 

the

 

MAX/MIN

 

key

 

and

 

the

 

display

 

icon

 

"

MIN

"

 

will

 

appear.

 

The

 

meter

 

will

 

display

 

and

 

hold

 

the

 

minimum

 

reading

 

and

 

will

 

update

 

only

 

when

 

a

 

new

 

“min”

 

occurs

 

3.

 

Press

 

the

 

MAX/MIN

 

key

 

and

 

a

 

blinking

 

MAX

 

MIN

 

will

 

appear.

 

The

 

meter

 

will

 

display

 

the

 

present

 

reading,

 

but

 

will

 

continue

 

to

 

update

 

and

 

store

 

the

 

max

 

and

 

min

 

readings.

 

4.

 

To

 

exit

 

MAX/MIN

 

mode

 

press

 

and

 

hold

 

the

 

MAX/MIN

 

key

 

for

 

2

 

seconds.

 

Temperature

 

Units

 

(

˚

F

 

/

 

˚

C)

 

The

 

temperature

 

unit

 

selection

 

switch

 

is

 

located

 

in

 

the

 

battery

 

compartment.

 

To

 

change

 

the

 

units,

 

remove

 

the

 

battery

 

door,

 

lift

 

out

 

the

 

battery

 

and

 

set

 

the

 

switch

 

for

 

the

 

desired

 

units.

 

 

LCD

 

Backlight

 

Button

 

The

 

LCD

 

is

 

equipped

 

with

 

backlighting

 

for

 

easier

 

viewing,

 

especially

 

in

 

dimly

 

lit

 

areas.

 

Press

 

the

 

backlight

 

button

 

to

 

turn

 

the

 

backlight

 

on.

 

Press

 

again

 

to

 

turn

 

the

 

backlight

 

off.

  

Units Switch

F

C

Содержание EX850

Страница 1: ...USER MANUAL Extech EX850 True RMS 1000 Amp Clamp Meter BluetoothTM and AndroidTM ready Patented ...

Страница 2: ...nual for further information This symbol adjacent to a terminal indicates that under normal use hazardous voltages may be present Double insulation SAFETY NOTES Do not exceed the maximum allowable input range of any function Do not apply voltage to meter when resistance function is selected Set the function switch OFF when the meter is not in use Remove the battery if meter is to be stored for lon...

Страница 3: ... terminals are not live If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired This device is not a toy and must not reach children s hands It contains hazardous objects as well as small parts that the children could swallow In case a child swallows any of them please contact a physician immediately Do not leave batteries and...

Страница 4: ...switch Display icons Description HOLD Data Hold Minus sign Negative reading display 0 to 3999 Measurement display digits ZERO Zero P Peak value AUTO Auto Range mode DC AC Direct Alternating Current MAX Max reading MIN Min reading Low battery mV or V Milli volts or Volts Voltage Ω Ohms Resistance A Amperes Current F Farad Capacitance Hz Hertz Frequency oF and oC Fahrenheit and Celsius units Tempera...

Страница 5: ...fset values and improves accuracy for DC current measurements To perform a zero select ADC and with no conductor in the jaw 1 Press the DC ZERO button to zero the display ZERO will appear in the display The offset value is now stored and remo ved from all measurements 2 To view the stored value press the DC ZERO button ZERO will flash and the stored value will be displayed 3 To exit this mode pres...

Страница 6: ...t lead banana plug into the CAP positive jack 3 Press MODE to zero any stray capacitance 4 Touch the test probe tips across the part under test 5 Read the capacitance value in the display 6 The display will indicate the proper decimal point and value Note For very large values of capacitance measurement time can be several minutes before the final reading stabilizes Frequency Measurements 1 Set th...

Страница 7: ...ve COM terminal and the red test lead into the Ω positive terminal 2 Set the function switch to the position 3 Use the MODE button to select continuity The display icons will change when the MODE button is pressed 4 Touch the test probe tips across the circuit or component under test 5 If the resistance is 40 Ω a tone will sound Diode Test 1 Insert the black test lead banana plug into the negative...

Страница 8: ...l for hazard if viewed directly for extended periods of time IR Spot to Distance Diagram The 8 1 spot to distance ratio determines the size of the measured surface area with respect to the distance the meter is held away from the surface IR Measurement Notes 1 The object under test should be larger than the spot target size calculated by the field of view diagram 2 If the surface of the object und...

Страница 9: ...s off Note If the Function switch position is changed after a calibration the Peak Hold calibration must be repeated for the new function selected MAX MIN 1 Press the MAX MIN key to activate the MAX MIN recording mode The display icon MAX will appear The meter will display and hold the maximum reading and will update only when a new max occurs 2 Press the MAX MIN key and the display icon MIN will ...

Страница 10: ... Play Store 2 Perform a search to obtain the EX850 from the list of available devices 3 Pair the meter with the Android device tablet or phone in Settings under Bluetooth Use code 1234 to pair the EX850 to the Android device 4 Start the ExViewTM EX850 application tap CONNECT icon and the paired list will appear Tap on the EX850 meter from the paired list 5 The upper left corner of the App should i...

Страница 11: ...mful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the recei...

Страница 12: ...s and turn OFF the meter before opening the case Do not operate the meter with an open case Cleaning and Storage Periodically wipe the case with a damp cloth and mild detergent do not use abrasives or solvents If the meter is not to be used for 60 days or more remove the battery and store it separately Battery Replacement 1 Remove the Phillips head screw that secures the rear battery door 2 Open t...

Страница 13: ... 1 0 10d 4 000 VAC 1 5 5d 40 00 VAC 400 0 VAC 1000 VAC 2 0 5d DC Voltage 400 0 mVDC 0 8 2d 4 000 VDC 1 5 2d 40 00 VDC 400 0 VDC 1000 VDC 2 0 2d Resistance 400 0Ω 1 0 4d 4 000kΩ 1 5 2d 40 000kΩ 400 0kΩ 4 000MΩ 2 5 3d 40 00MΩ 3 5 5d Capacitance 4 000nF 5 0 30d 40 00nF 5 0 20d 400 0nF 3 0 5d 4 000µF 40 00µF 400 0µF 4 0 10d 4 000mF 10 10d 40 00mF unspecified Frequency 4 000kHz 1 5 2d Sensitivity 100V ...

Страница 14: ...unction Range and Resolution Accuracy of reading digits Temperature type K 4 to 1400o F 3 rdg 9o F 20 to 760o C 3 rdg 5o C Temp IR 58 to 4 F 9 F 4 to 518 F 2 0 reading or 4 F whichever is 50 to 20 C 5 C 20 to 270 C 2 0 reading or 2 C whichever is ...

Страница 15: ...rms AAC and VAC Crest Factor 3 0 in 40A and 400A ranges 1 4 in 1000A range 50 60Hz and 5 to 100 of range Operating Temperature 5 C to 40 C 41 F to 104 F Storage Temperature 20 C to 60 C 4 F to 140 F Operating Humidity Max 80 up to 31 C 87 F decreasing linearly to 50 at 40 C 104 F Storage Humidity 80 Operating Altitude 2000m 7000ft maximum Battery One 1 9V Battery NEDA 1604 Auto power OFF After app...

Отзывы: