EX613-EU-EN-V2.6-4/12
14
General Specifications
Clamp jaw opening
32mm (1.25") approx.
Display
Dual 40,000/4,000 count backlit LCD
Non-Contact Voltage
100 to 600VAC
Continuity check
Threshold 50
Ω
; Test current < 0.5mA
Diode test
Test current of 0.3mA typical;
Open circuit voltage
[
2.8VDC typical
Low Battery indication
Battery symbol is displayed
Over-range indication
‘OL’
display
Measurement rate
2 readings per second, nominal
Peak detector
>1ms
Thermocouple sensor
Type K thermocouple required
Fuse
500mA, ceramic fast blow
Input Impedance
10M
Ω
(VDC and VAC)
AC bandwidth
50 to 400Hz (AAC and VAC)
AC response
True rms (AAC and VAC)
Crest Factor
3.0 in 40A and 400A ranges, 1.4 in 1000A range (50/60Hz and 5% to
100% of range)
Operating Temperature
5
°
C to 40
°
C (41
°
F to 104
°
F)
Storage Temperature
-20
°
C to 60
°
C (-4
°
F to 140
°
F)
Operating Humidity
Max 80% up to 31
°
C (87
°
F) decreasing linearly to 50% at 40
°
C
(104
°
F)
Storage Humidity
<80%
Operating Altitude
2000 meters (7000ft) maximum.
Battery
One (1) 9V Battery (NEDA 1604)
Auto power OFF
After approx. 30 minutes, with disable
Dimensions & Weight
241x96x44.5mm (9.5x3.8x1.75”); 386g (13.6 oz)
Safety
For indoor use and in accordance with the requirements for double
insulation to IEC1010-1 (2001): EN61010-1 (2001) Overvoltage
Category III 600V and Category II 1000V, Pollution Degree 2.
Approvals
CE,
Copyright
©
2012 Extech Instruments Corporation (a FLIR company)
All rights reserved including the right of reproduction in whole or in part in any form.