EX210T-EU-EN V1.1 8/12
11
Specifications
Function Range
Resolution
Accuracy
200 mV
0.1 mV
(0.8% r 6 digits)
2V 0.001V
20V 0.01V
(0.5% r 2 digits)
200V 0.1V
DC Voltage
600V 1V
(0.8% r 2 digits)
200 mV
0.1 mV
2V 0.001V
20V 0.01V
200V 0.1V
600V 1V
(1.5% r 6 digits)
AC Voltage
(50/60Hz)
True RMS
All AC voltage ranges are specified from 5% of range to 100% of range
200
A 0.1
A
2000
A 1
A
20 mA
0.01 mA
200 mA
0.1 mA
(1.5% r 5 digits)
2.000 0.001
A
10 A
0.01 A
(2.5% r 5 digits)
DC Current
Note:10A for 30 sec max
200
A 0.1
A
2000
A 1
A
20 mA
0.01 mA
200 mA
0.1 mA
(1.5% r 8 digits)
2.000 0.001
A
10 A
0.01 A
(3.0% r 5 digits)
AC Current
(50/60Hz)
True RMS
Note: 10A for 30 sec max
NOTE:
Accuracy is stated at 18
o
C to 28
o
C (65
o
F to 83
o
F) and less than 75% RH.