EX210_EX210T-en-US_v1.5 9/15
11
Specifications
Function
Range
Resolution
Accuracy
DC Voltage
200 mV
0.1 mV
(0.8% r 6 digits)
2V
0.001V
(0.5% r 2 digits)
20V
0.01V
200V
0.1V
(0.8% r 2 digits)
600V
1V
AC Voltage
(50/60Hz)
True RMS
(EX210T only)
200 mV
0.1 mV
(1.5% r 6 digits)
2V
0.001V
20V
0.01V
200V
0.1V
600V
1V
All AC voltage ranges are specified from 5% of range to 100% of range
DC Current
200 A
0.1 A
(1.5% r 5 digits)
2000 A
1 A
20 mA
0.01 mA
200 mA
0.1 mA
2.000
0.001 A
(2.5% r 5 digits)
10 A
0.01 A
Note:10A for 30 sec max
AC Current
(50/60Hz)
True RMS
(EX210T only)
200 A
0.1 A
(1.5% r 8 digits)
2000 A
1 A
20 mA
0.01 mA
200 mA
0.1 mA
2.000
0.001 A
(3.0% r 5 digits)
10 A
0.01 A
Note: 10A for 30 sec max
NOTE:
Accuracy is stated at 18
o
C to 28
o
C (65
o
F to 83
o
F) and less than 75% RH.