background image

 

      

  ET60-en-es-fr_V1.0   3/17 

USER MANUAL 

Model ET60 
Voltage/Continuity 
Tester 

 

 

Introduction 

The ET60 is an AC/DC 
Voltage tester with 
continuity check, NCV 
detector and a work light. 
The attached test leads are connected with 
24” of 18-gauge wire rated at 600V. The 6” 
test lead handles include spring loaded 
protective tip sleeves. 

AC/DC Voltage 

Always test on a known live circuit before 
use. 
To check for voltage, insert test leads into 
outlet or carefully touch test leads to the 
electrical contacts or circuit to be tested. If 
voltage is present, the LED indicators will 
illuminate in the correct range.  
Use the highest illuminated range to 
determine the correct voltage. If the 
readings are greater than 120VAC or 48VDC, 
the meter will vibrate. 

Non-Contact Voltage (NCV) 

Always test on a known live circuit before 
use. 
To check for non-contact voltage, place the 
meter near a source of electrical energy. 
Press the ON/OFF button to measure NCV 
voltage. Note that the tip of the meter offers 
the highest sensitivity. If voltage is present, 
the LED indicators will illuminate. 

Continuity 

WARNING: To avoid electric shock, never 
measure continuity on circuits that have 
voltage on them. 

Touch the test leads to the circuit under 
test. The bulb at the top of the meter will 
illuminate if there is continuity. 

Worklight 

Press the ON/OFF button to activate the 
work light and to measure NCV. 
 
 
 
 
 
 
 

WARNINGS:  

 

Risk of Electric Shock. Always check 
proper operation on a known live circuit 
before using.  

 

Never ground yourself when making 
electrical measurements.  

 

Do not use outside of rated voltages. 

 

Do not use in wet weather. 
 

CAUTION

Use extreme caution when 

checking electrical circuits to avoid injury due 
to electrical shock. FLIR Systems, Inc. 
assumes basic knowledge of electricity on 
the part of the user and is not responsible for 
any injury or damages due to improper use 
of this tester.

 

 
 

SPECIFICATIONS 

Non-Contact Voltage Range: 90~1000 
volts AC 
DC Voltage Range: 
7 LED indicators from 
6~220 volts 
AC Voltage Range: 7 LED indicators from 
24~600 volts 
AC Voltage Frequency: 45~66 Hz 
Power: Two 1.5V AAA batteries 
Operating Temp.: 32~122°F (0~50°C) 
Operating Humidity: 70% RH Max 
Use clean, dry cloth to clean 

 

OVERVOLTAGE CATEGORY III 
Equipment of OVERVOLTAGE CATEGORY III is 
equipment in fixed installations. 
Note – Examples include switches in the 
fixed installation and some equipment for 
industrial use with permanent connection 
to the fixed installation.

 

 

Double Insulation: The meter is 
protected by double insulation or 
reinforced insulation. 
 

 File No. 3160913 

 

 

Copyright © 2017 FLIR Systems, Inc. 

All rights reserved including the right of reproduction in 

whole or in part in any form 

ISO-9001 Certified 

www.extech.com 

 
 
 
 
 
 
 

Отзывы: