background image

   

                                       

EC170-EU-EN V1.1   7/13

 

Battery

 

Installation

 

The

 

meter

 

is

 

shipped

 

with

 

the

 

four

 

(4)

 

LR44

 

button

 

batteries

 

removed.

 

The

 

user

 

must

 

install

 

the

 

batteries

 

before

 

the

 

meter

 

can

 

be

 

used.

 

Refer

 

to

 

accompanying

 

diagram.

 

1.

 

Unscrew

 

the

 

battery

 

compartment

 

cover

 

(top

 

of

 

meter)

 

in

 

a

 

counter

clockwise

 

direction.

 

Please

 

do

 

not

 

discard

 

the

 

black

 

washer.

  

2.

 

Install

 

the

 

four

 

(4)

 

LR44

 

button

 

batteries,

 

carefully

 

orienting

 

the

 

batteries

 

and

 

observing

 

polarity.

 

3.

 

Replace

 

the

 

battery

 

compartment

 

cover.

 

4.

 

Please

 

remove

 

the

 

batteries

 

while

 

the

 

meter

 

is

 

not

 

in

 

use

 

for

 

long

 

periods.

 

Never

 

dispose

 

of

 

used

 

batteries

 

or

 

rechargeable

 

batteries

 

in

 

household

 

waste.

 

As

 

consumers,

 

users

 

are

 

legally

 

required

 

to

 

take

 

used

 

batteries

 

to

 

appropriate

 

collection

 

sites,

 

the

 

retail

 

store

 

where

 

the

 

batteries

 

were

 

purchased,

 

or

 

wherever

 

batteries

 

are

 

sold.

 

Disposal:

 

Do

 

not

 

dispose

 

of

 

this

 

instrument

 

in

 

household

 

waste.

 

The

 

user

 

is

 

obligated

 

to

 

take

 

end

of

life

 

devices

 

to

 

a

 

designated

 

collection

 

point

 

for

 

the

 

disposal

 

of

 

electrical

 

and

 

electronic

 

equipment.

  

 

Other

 

Battery

 

Safety

 

Reminders

 

a.

 

Never

 

dispose

 

of

 

batteries

 

in

 

a

 

fire.

 

Batteries

 

may

 

explode

 

or

 

leak.

 

b.

 

Never

 

mix

 

battery

 

types.

 

Always

 

install

 

new

 

batteries

 

of

 

the

 

same

 

type.

 

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание EC170

Страница 1: ...USER GUIDE Salinity Meter Pen Style Water Quality Meter Model EC170 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 2: ... Updates and Customer Support Features IP65 Waterproof housing Automatic Ranging and Manual Ranging capability Dual Display with ATC automatic temperature compensation Data hold for freezing displayed readings Low battery indicator Automatic power off for maximum battery efficiency Switchable temperature units of measure o C o F Multi point and one touch calibration features Pocket sized powered b...

Страница 3: ...se for long periods Never dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dispose of this instrument in household waste The user is obligated to take end of life devices to a designat...

Страница 4: ... 3 Primary measurement reading 4 Parts per thousand salinity units ppm parts per million are not used in this meter 5 Temperature reading 6 Temperature units of measure 7 Battery strength indicator 8 Calibration icon Keypad Description 1 Power ON OFF and SET button 2 Down Arrow Data Hold and Calibration button 3 Up arrow button www GlobalTestSupply com Find Quality Products Online at sales GlobalT...

Страница 5: ...one of these two ranges is selected automatically to provide the best resolution and accuracy for each given measurement However MANUAL Range mode can also be used where range 1 and range 2 can be selected manually 5 Press and hold the UP arrow button the number 1 range 1 will appear on the lower right of the LCD and ran range will appear at the center of the LCD 6 Release the button and the meter...

Страница 6: ... display while stabilization is taking place in measurement mode When stabilization is achieved the meter s icon will stop flashing Press the HOLD button to freeze a displayed reading Press again to release the display Salinity Measurement 1 Read the Measurement Preparation section above before continuing 2 Insert the electrode into the sample ensuring that the electrodes are completely submersed ...

Страница 7: ...ll be flashing 3 Use the arrow buttons to select y for YES RESET or n for NO RESET 4 Press the SET button momentarily to confirm the setting 5 Press and hold the SET button for at least 2 seconds to return to the normal operation mode or press the up arrow button momentarily to move to Parameter P4 see below Parameter P4 Calibration Review for Range 1 and Range 2 Concentrations 1 If continuing fro...

Страница 8: ...s with the standardizing solution to a depth of at least 3 cm 1 2 each 4 Switch the meter ON 5 Rinse the probe in one of the sample cup solutions gently stirring the probe Rinsing could remove contaminants that could affect calibration and cause measurement errors 6 Dip the rinsed probe into the other sample cup solution Tap or move the electrode in the sample to dislodge air bubbles Let the probe...

Страница 9: ... dip the electrode into a solution at an oblique angle Vertical dipping can cause many air bubbles to adhere Gently tap the bottom of the solution container while stirring the electrode in the solution Air can be blown across the electrode before dipping it into the solution Error Codes Refer to the Table below for details on Error Codes displayed by the meter Code Description Suggestions SALINITY...

Страница 10: ...y to TDS conversion factor Calibration One point calibration per range Auto Power OFF After 20 minutes of inactivity Data Hold Freezes displayed reading Automatic Temperature Compensation ATC 0 to 50 C 32 to 122 F Waterproof IP65 rated Temperature Coefficient Built in NaCl temperature coefficient Operating Conditions Temperature 0 to 50 C 32 to 122 F 80 RH Storage Conditions Temperature 0 to 60 C ...

Отзывы: