background image

EXTECH

 

INSTRUMENTS

 

4

                                               

CO50

en

GB_V1.2

   

12/14

 

Operation

 

 

POWER

 

THE

 

METER

 

Plug

 

the

 

AC

 

adaptor

 

into

 

meter

 

and

 

receptacle

 

to

 

turn

 

on

 

the

 

meter.

 

Reset

 

the

 

date

 

and

 

time

 

each

 

time

 

the

 

meter

 

power

 

is

 

cycled.

 

Remove

 

the

 

adaptor

 

or

 

switch

 

off

 

the

 

AC

 

power

 

source

 

to

 

shut

 

down

 

the

 

meter.

 

 

GETTING

 

STARTED

 

All

 

LCD

 

display

 

lines

 

will

 

switch

 

ON

 

when

 

power

 

is

 

applied

 

to

 

meter.

 

The

 

LED

 

indicator

 

will

 

also

 

be

 

ON

 

steady

 

with

 

an

 

orange

 

color.

 

The

 

display

 

will

 

now

 

auto

 

zero.

 

Auto

 

zero

 

takes

 

approximately

 

60

 

seconds

 

and

 

then

 

the

 

meter

 

counts

 

down

 

from

 

9

 

to

 

0.

 

The

 

meter

 

is

 

now

 

in

 

the

 

normal

 

operating

 

mode.

 

 

When

 

attempting

 

to

 

manually

 

store

 

the

 

current

 

CO

 

reading,

 

the

 

LED

 

light

 

turns

 

green

 

for

 

one

 

second

 

and

 

a

 

short

 

beeper

 

tone

 

will

 

sound.

  

 

The

 

LCDs

 

show

 

the

 

current

 

CO

 

value

 

in

 

ppm

 

(top),

 

ambient

 

temperature/relative

 

humidity

 

(middle),

 

and

 

the

 

date

 

and

 

time

 

(bottom).

 

 

Toggle

 

the

 

temperature

 

units

 

by

 

pressing

 

and

 

holding

 

the

 

C/F/%RH

 

button.

 

 

SETTING

 

DATE/TIME

 

In

 

normal

 

operation,

 

the

 

meter

 

alternates

 

the

 

date

 

and

 

time

 

displays.

 

Press

 

the

 

SET

 

button

 

to

 

switch

 

between

 

the

 

12

hour

 

system

 

(am/pm)

 

and

 

the

 

24

hour

 

system.

 

Note

 

that

 

the

 

default

 

time

 

display

 

is

 

a

 

24

hour

 

clock

 

format.

      

1.

 

Press

 

and

 

hold

 

SET

 

for

 

3

 

seconds

 

to

 

see

 

image

 

at

 

right.

 

2.

 

Press

 

 

to

 

decrease

 

a

 

number

 

or

 

press

 

 

to

 

increase

 

a

 

number

  

3.

 

Press

 

SEL/RECALLECALL

 

to

 

scroll

 

through

 

the

 

YEAR

MONTH

DAY

 

4.

 

When

 

finished

 

changing

 

the

 

Date,

 

press

 

SET

 

to

 

change

 

the

 

Time

 

5.

 

Press

 

 

to

 

decrease

 

number

 

or

 

press

 

 

to

 

increase

 

number

  

6.

 

Press

 

SEL/RECALLECALL

 

to

 

scroll

 

through

 

HR

MIN

SEC

 

7.

 

Press

 

SET

 

to

 

access

 

the

 

alarm

 

setting

 

(see

 

Alarm

 

section).

 

8.

 

To

 

exit,

 

press

 

and

 

hold

 

SET

 

for

 

3

 

seconds.

 

 

Содержание CO50

Страница 1: ...USER GUIDE Desktop Carbon Monoxide Monitor Model CO50...

Страница 2: ...art measurement technology Easy to use intended for indoor air quality monitoring Bright multicolor LED representing Recording Green Alarm Red Startup Orange 99 data point memory User adjustable CO Al...

Страница 3: ...DE Button with down arrow Decrease a value Review Maximum MAX reading Meter Description 1 Top LCD display for CO concentration 2 Middle LCD display for RH and temperature 3 Bottom LCD display Time and...

Страница 4: ...er tone will sound The LCDs show the current CO value in ppm top ambient temperature relative humidity middle and the date and time bottom Toggle the temperature units by pressing and holding the C F...

Страница 5: ...ss SET again to skip the Time setting Set the Time if desired per earlier instructions 4 A flashing digit will appear Use the up and down arrows to increase decrease the alarm threshold Press SEL RECA...

Страница 6: ...m temporarily From the normal measurement mode press the SET MODE button at the same time the bell icon disappears After 4 minutes the alarm will turn on again automatically To comply with UL regulati...

Страница 7: ...ntil Clr appears on LCD The LCD automatically returns to normal mode The illustration below on the left shows a manually recorded reading reading number 05 in this case the middle illustration shows t...

Страница 8: ...distance Temperature range 10 to 60 o C 14 to 140 o F Temperature resolution 0 1 o C o F Temperature Accuracy 0 6 o C 1 2 o F RH range 10 to 90 RH RH Resolution 0 1 RH RH Accuracy 5 RH at 25 o C other...