background image

AN510-en-GB_V1.0   5/17 

MAX-MIN Recording 

In this mode, the meter records the maximum and minimum values over time. 

1.

 

Short press the 

R

 button to enter the Record mode. The 

 record icon will appear on the 

display. The maximum and minimum values will be recorded and updated during the 

measurement period. 

2.

 

Short press the 

R

 button to stop the Max-Min recording. The   icon and the MAX value 

that occurred during the recording period will be displayed.  

3.

 

Short press the 

R

 button to display the   icon along with the MIN value that occurred 

during the recording period. 

4.

 

Short press the 

H

 button to clear the memory and start a new max/min measurement 

period.  

5.

 

Long press the 

R

 button to exit record mode. 

 

Maintenance 

Battery Replacement 

1.

 

Power OFF the meter. 

2.

 

Remove the flat head screw that secures the battery compartment at the back of the 

meter.  

3.

 

Open the battery compartment and replace the 3 AAA batteries observing correct polarity. 

Re-assemble the meter before use 

Safety: Please dispose of batteries responsibly; never dispose of batteries in a fire, batteries may 

explode or leak. If the meter is not to be used for 60 days or more, remove the battery and store 

separately. 
 

 

Never dispose of used batteries or rechargeable batteries in household waste. 

As consumers, users are legally required to take used batteries to appropriate 

collection sites, the retail store where the batteries were purchased, or wherever 

batteries are sold. 

Disposal: 

Do not dispose of this instrument in household waste. The user is obligated 

to take end-of-life devices to a designated collection point for the disposal of electrical 

and electronic equipment. 

 

 

Cleaning and Storage 

Periodically wipe the case with a damp cloth and mild detergent; do not use abrasives or 

solvents.  

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание AN510

Страница 1: ...USER MANUAL CFM CMM Thermo Anemometer Model AN510 Additional User Manual Translations available at www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 2: ...of this User Manual Product Updates and Customer Support Features Built in microprocessor circuit Low friction ball bearing mounted wheel provides high accuracy LCD with backlight for easy viewing Compact light weight easy to use design Wristlet for easy one handed operation Safety Please read the entire User Manual and Quick Start before operating this device Use the meter only as specified and d...

Страница 3: ...button 7 Unit Button 8 SET and button 9 RECORD button 10 Hold Button LCD Description 1 Air Velocity 2 Record 3 Max 4 Min 5 Hold 6 Air Flow 7 Battery Indicator 8 Auto Power OFF 9 Unit of Measure 10 Temperature Units 11 Lower LCD Display 12 Upper LCD Display 13 Type K Temperature www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 4: ...s programmed to be ON see the SET function section later in this manual Mode Press the mode M button to select the mode of operation Each press of the button will step through the three modes 1 Air Velocity Displays the air speed through the vane in the units selected The AIR icon will appear in the display Air velocity will be displayed on the upper part of the LCD Air temperature will be display...

Страница 5: ... normal operation Setting Dimensions for Airflow Measurements The area of the air duct in square feet or square meters must be entered to perform air flow volume measurements Remember to convert square inches or centimeters to square feet or square meters for area measurements before continuing See Useful equations and Conversions later in this manual for additional information 1 Select Air Flow w...

Страница 6: ...t at the back of the meter 3 Open the battery compartment and replace the 3 AAA batteries observing correct polarity Re assemble the meter before use Safety Please dispose of batteries responsibly never dispose of batteries in a fire batteries may explode or leak If the meter is not to be used for 60 days or more remove the battery and store separately Never dispose of used batteries or rechargeab...

Страница 7: ... Consumption Approximately 5mA DC Weight 136g 4 8 oz Dimensions HxWxD 141x 57x 25mm 5 5 x 2 3 x 1 1 Air Velocity Units Range Resolution Accuracy ft min 80 to 3937 1 3 F S m s 0 4 to 20 0 0 1 km h 1 4 to72 0 0 1 MPH 0 9 to 44 7 0 1 knots 0 8 to 38 8 0 1 C 0 to 50 0 1 1 2 C F 32 to 122 0 1 2 5 F Air Flow CMM m3 0 024 to 36000 0 001 0 01 0 1 1 0 001 0 01 0 1 1 10 x10 100 x100 CFM ft3 0 847 to 1271300...

Страница 8: ... 0 00508 1 0 00987 0 01829 0 01138 1 knot 0 5144 101 27 1 1 8519 1 1523 1 km h 0 2778 54 69 0 54 1 0 6222 1 MPH 0 4464 87 89 0 8679 1 6071 1 Copyright 2017 FLIR Systems Inc All rights reserved including the right of reproduction in whole or in part in any form ISO 9001 Certified Width W Height H Area A Width W x Height H CFM ft3 min Air Velocity ft min x Area ft2 CMM m3 min Air Velocity m sec x Ar...

Отзывы: