AN400  V3.0  12/06 

Operation 

Connecting the Vane Cup 

1.  Place the cup vane on the top of the meter housing. 

2.  Rotate the top screw in a counter-clockwise 

 direction 

until the screw is secured.  

 

 

 

 

 

 

 

Meter Power 

1.  Press the POWER button to turn the meter on. If the display does not switch on, check 

that four AAA batteries are installed. To access the battery compartment, remove the 
battery cover by rotating it in a counter-clockwise direction. 

2.  Press the POWER button to turn the meter off. 
3.  The meter is equipped with an AUTO POWER OFF feature. The meter automatically 

shuts off after 10 minutes to conserve battery energy. To disable this feature, press the 
REC button to enable the MIN/MAX function. 

Measuring Air Velocity and Temperature 

1.  Hold the meter vertically and place the cup sensor in the air stream under test. 
2.  Read the Air Velocity and Temperature measurements directly on the LCD display. 

Note

: The temperature sensor is located in the upper right of the front panel. To avoid 

affecting the temperature reading, hold the lower portion of the meter when making 
measurements. 

Selecting the Temperature unit of measure (

o

C/

o

F) 

Press and Hold (>2 seconds) the REC/

o

C/

o

F key to toggle the temperature unit of 

measure. The display will indicate the currently selected unit of measure.  

Note:

 Temperature unit of measure cannot be changed if the Data Hold or Record function 

is on. 

Selecting the Air Velocity unit of measure 

To change the unit of measure for Air Velocity measurement, press and hold (>2 seconds) 
the HOLD/Unit button. The display will sequence through the measurement units. When 
the desired unit of measure is displayed, release the button. The current setting will be 
retained even after the meter is powered off.  

Note: 

Unit of Measure cannot be changed if the Data Hold or Record function is on. 

Data Hold 

To freeze the LCD display, momentarily press the HOLD button. The 'HOLD' icon will 
appear on the LCD and the reading will remain unchanged. Momentarily press the HOLD 
button again to return to normal operation (the 'HOLD' icon will switch off). 

Содержание AN400

Страница 1: ...User s Guide Cup Thermo Anemometer Model AN400 ...

Страница 2: ...low An internal thermistor allows the AN400 to measure air temperature in Centigrade or Fahrenheit units This meter is shipped fully tested and calibrated and with proper use will provide years of reliable service Meter Description 1 Cup vane 2 Temperature sensor 3 POWER On Off Logger Store data with REC in display Step through and recall stored data 4 HOLD Freeze display Unit Select measured unit...

Страница 3: ...r is located in the upper right of the front panel To avoid affecting the temperature reading hold the lower portion of the meter when making measurements Selecting the Temperature unit of measure o C o F Press and Hold 2 seconds the REC o C o F key to toggle the temperature unit of measure The display will indicate the currently selected unit of measure Note Temperature unit of measure cannot be ...

Страница 4: ...y memory locations remaining will appear in the lower display for 2 seconds and then the normal display will return 3 To exit the datalogger press and hold the REC button for 2 seconds The REC icon will disappear 4 To recall the stored data momentarily press the HOLD button to display the HOLD icon 5 Momentarily press the REC button to display the total number of data points stored in memory ttL w...

Страница 5: ...plies on sensors and cables If it should become necessary to return the instrument for service during or beyond the warranty period contact the Customer Service Department at 781 890 7440 ext 210 for authorization or visit our website at www extech com for contact information A Return Authorization RA number must be issued before any product is returned to Extech The sender is responsible for ship...

Страница 6: ... Power Supply 4 x 1 5V AAA batteries Power Consumption Approx 6 8mA DC typical battery life approx 150 hrs Weight 0 4 lbs 181g Dimensions Main instrument 7 5 x 1 6 x1 3 190 x 40 x 32mm Cup Vane 5 3 135mm diameter Air Velocity Range Specifications Measurement Range Resolution Accuracy of full scale ft min feet per minute 144 6895 ft min 1 ft min 2 40 ft min m s meters per second 0 9 35 0 m s 0 1 m ...

Отзывы: