Specifications

 

Air

 

Velocity

 

Range

 

Resolution

 

Accuracy

 

m/s

 

(meters

 

per

 

second)

 

0.2

 ‐ 

30

 

m/s

 

0.01

 

m/s

 

±

 

(1.5%

 

rdg

 

+

 

0.3

 

m/s)

 

fpm

 

(feet

 

per

 

minute)

 

40

 

 

5900

 

fpm

 

1

 

fpm

 

±

 

(1.5%

 

rdg

 

+

 

59

 

fpm)

 

Air

 

Flow

 

(Volume)

 

Range

 

Resolution

 

Area

 

Range

 

CMM

 

(cubic

 

meters/min)

0

99999

 

m

3

/min

 

0.1

 

up

 

to

 

9999.9

 

then

 

1.0

 

0

 

to

 

99999cm

2

 

CFM

 

(cubic

 

ft/min)

 

0

99999

 

ft

3

/min

 

0.1

 

up

 

to

 

9999.9

 

then

 

1.0

 

0

 

to

 

99999in

2

 

Air

 

Temperature

 

Range

 

Resolution

 

Accuracy

 

o

C/F

 

20

 

to

 

60

o

C

 

(

4

 

to

 

140

o

F)

 

0.1

o

C/F

 

±0.6°C

 

(

20

 

to

 

50°C)

 

±1.2°C

 

(51

 

to

 

60°C)

 

±

 

1.1°F

 

(

5

 

to

 

122°F)

 

±

 

2.2°F

 

(123

 

to

 

140°F)

 

Circuit

 

Custom

 

LSI

 

microprocessor

 

Display

 

Dual

 

function

 

13

 

mm

 

(0.5")

 

4

digit

 

LCD

 

Sampling

 

rate

 

1

 

reading

 

per

 

second

 

approx.

 

Air

 

velocity/flow

 

sensor

  

Conventional

 

angled

 

vane

 

arms

 

with

 

low

friction

 

ball

 

bearing

 

Temperature

 

sensor

 

NTC

type

 

precision

 

thermistor

 

Automatic

 

Power

 

off

 

Auto

 

shut

 

off

 

after

 

20

 

minutes

 

to

 

preserve

 

battery

 

life

 

(sleep

 

mode)

 

Operating

 

Temperature

 

0°C

 

to

 

50°C

 

(32°F

 

to

 

122°F)

 

Storage

 

Temperature

 

10

 

to

 

50

o

C

 

(14

 

to

 

122

o

F)

 

Operating

 

Humidity

 

<80%

 

RH

 

Storage

 

Humidity

 

<90%

 

RH

 

Operating

 

Altitude

 

2000

 

meters

 

(7000ft)

 

maximum

 

Battery

 

Power

 

Four

 

(4)

 

‘AAA’

 

1.5V

 

batteries

 

Battery

 

Life

 

>

 

40

 

hours

 

Battery

 

consumption

 

8.3

 

mA

 

DC

 

(approx.)

 

Weight

 

725g

 

(1.6

 

lbs.)

 

including

 

battery

 

and

 

probe

 

Dimensions

 

Main

 

instrument:

 

269

 

x

 

106

 

x

 

51mm

 

(10.6

 

x

 

4.2

 

x

 

2”)

 

 

Optional

 

Air

 

Flow

 

Adaptors:

 

 

Round

 

cone:

 

210mm

 

(8.3”)

 

Diameter

 

 

Square:

 

346

 

x

 

346mm

 

(13.6

 

x

 

13.6”)

 

 

 

www.

.com

[email protected]

1.800.561.8187

Содержание AN300

Страница 1: ...USER GUIDE Large Vane CFM CMM Thermo Anemometer Model AN300 www com information itm com 1 800 561 8187 ...

Страница 2: ...nd personal injury Read and understand this user manual before operating the meter Inspect the condition of the probe and the meter for any damage before operating the meter Repair or replace damage before use If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired This device should not be made available to children It contai...

Страница 3: ... arrow button 4 L mode and down arrow button 5 ON OFF Power and SET button 6 HOLD MAX MIN and left arrow Enter button 7 Unit of measure symbol for lower display row 8 Unit of measure symbol for upper display row 9 Air Velocity Vane Meter Description rear 10 Air temperature sensor 11 Battery compartment www com information itm com 1 800 561 8187 ...

Страница 4: ... for a timed recording session and in the SETUP mode for configuring the meter Please review the AVERAGE and SETUP mode sections for details Press and hold for 2 seconds to access the Multi Point Average and Timed Average modes the AVG icon switches ON Detailed instructions for these modes are provided later in this guide In the Setup mode press to select a category or to increase a value refer to...

Страница 5: ...tional Cone and Funnel attachment icons 4 Units of measure for duct area programming 5 Vane indicator flashes very briefly on power up 6 Display HOLD icon 7 MAX mode icon 8 MIN mode icon 9 Recording icon 10 Elapsed Timer icon 11 AVG mode icon 12 Battery status icon 13 Unit of measure icons Full list shown Available units of measure icons vary by model www com information itm com 1 800 561 8187 ...

Страница 6: ...en Imperial and Metric units of measure refer to the SETUP mode section 7 To measure the Air Volume of a duct first measure the duct s area see the Appendix for area calculations and then enter the area value in the meter s SETUP mode in in 2 or cm 2 After the area value has been entered press the L mode button to switch the lower display from Air Temperature to Air Volume Place the meter in the a...

Страница 7: ...the AVG display icon and the associated black dot will switch ON 2 Press the HOLD button momentarily to record one reading The upper display digits will show the reading s memory location number and the lower display will show the measured value Press the HOLD button again to take and store another reading the memory location number will increment by one and the current reading will be stored in t...

Страница 8: ... return to the P1 0 display 4 Press either arrow button to move to the P2 0 AREA option and follow the steps below P2 0 Area Size Selection 1 In setup mode from the P2 0 AREA display press HOLD to enter the AREA setting menu The LCD will show 99999 in the lower display with the left most digit flashing 2 Use the up arrow button change the flashing digit from 0 through 9 3 Use the down arrow button...

Страница 9: ...ttery compartment before attempting to use the meter EU users are legally bound by the Battery Ordinance to return used batteries to community collection points or wherever batteries accumulators are sold Disposal in household trash or refuse is prohibited Disposal Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle Other Battery Safety Reminder...

Страница 10: ...0 5 4 digit LCD Sampling rate 1 reading per second approx Air velocity flow sensor Conventional angled vane arms with low friction ball bearing Temperature sensor NTC type precision thermistor Automatic Power off Auto shut off after 20 minutes to preserve battery life sleep mode Operating Temperature 0 C to 50 C 32 F to 122 F Storage Temperature 10 to 50 o C 14 to 122 o F Operating Humidity 80 RH ...

Страница 11: ... the unit to Extech for repair if the E03 error message persists Air volume E03 Reading exceeds the meter s display limit Check that the AREA setting is correct in the Setup Mode E04 Air velocity error Return the meter to Extech if the error message persists Other Errors E32 Memory IC error Reboot the meter and check it again send it to Extech Instruments for repair if the error message persists N...

Страница 12: ...44 3 6 2 24 1 ft min 0 00508 1 0 00987 0 01829 0 01138 1 knot 0 5144 101 27 1 1 8519 1 1523 1 km h 0 2778 54 69 0 54 1 0 6222 1 MPH 0 4464 87 89 0 8679 1 6071 1 Copyright 2013 FLIR Systems Inc All rights reserved including the right of reproduction in whole or in part in any form ISO 9001 Certified www extech com Width W Height H Area A Width W x Height H CFM ft 3 min Air Velocity ft min x Area ft...

Отзывы: