Specifications
Air Velocity
Range
Resolution Accuracy (% of reading)
m/s (meters per sec)
0.40 - 30.00 m/s
0.01 m/s
± (3%rdg + 0.20 m/s)
km/h (kilometers/hour)
1.4 - 108.0 km/h
0.1 km/h
± (3%rdg + 0.8 km/hr)
ft/min (feet per minute)
80 – 5900 ft/min
1 ft/min
± (3%rdg + 40 ft/m)
mph (miles per hour)
0.9 – 67.0 mph
0.1 mph
± (3%rdg + 0.4 MPH)
knots (nautical MPH)
0.8 to 58.0 knots
0.1 knots
± (3%rdg + 0.4 knots)
Air Flow
Range
Resolution
Area
CMM (cubic meters/min)
0-9999 m
3
/min
1
0 to 9.999m
2
CFM (cubic ft/min)
0-9999 ft
3
/min
1
0 to 9.999ft
2
Air Temperature
Range
Resolution
Accuracy
-10 - 60
o
C (14 - 140
o
F)
0.1
o
C/F
±2.0
o
C (4.0
o
F)
Circuit
Custom LSI microprocessor circuit
Display
Dual function 13 mm (0.5") 4-digit LCD
Sampling rate
1 reading per second approx.
Sensors
Air velocity/flow sensor: Conventional angled vane arms with low-
friction ball bearing
Temperature sensor: NTC-type precision thermistor
Automatic Power off
Auto shut off after 20 minutes to preserve battery life
Operating Temperature
0°C to 50°C (32°F to 122°F)
Storage Temperature
-10 to 60
o
C (14 to 140
o
F)
Operating Humidity
<80% RH
Storage Humidity
<80% RH
Operating Altitude
2000 meters (7000ft) maximum
Battery
One 9 volt (NEDA 1604) battery
Battery life
80 hours approx. (if the Backlight is used continuously, battery life
will be reduced significantly)
Power Consumption
8.3 mA DC approx.
Weight
725g (1.6 lbs) including battery & probe
Dimensions
Main instrument: 178 x 74 x 33mm (7.0 x 2.9 x1.2")
Sensor Head: 70mm (2.75”) Inside Diameter
Sensor Head: 76.2mm (3.0”) Outside Diameter