User's Guide 

 
 

 

 

RPM Controller / Monitor 

 

Model 461960 

 

 

99 Washington Street 
Melrose, MA 02176 

Phone

 781-665-

1400

Toll Free 1-800-517-8431

 

Visit us at www.T

estEquipmentDepot.com

Back to the 

Extech 461960

 Product Page

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176

FAX 781.665.0780 - TestEquipmentDepot.com 

Содержание 461960

Страница 1: ...on Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com Back to the Extech 461960 Product Page Test Equipment Depot 800 517 8431 99 Washington Str...

Страница 2: ...ORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment a six month limited warranty applies to sensors and cables If it should become necess...

Страница 3: ...ble Insulation or Reinforced Insulation Safety Procedures Do not use fingers or any tool to touch the Wire Terminals Do not exceed 0 5A relay contact load The instrument contains no user serviceable p...

Страница 4: ...in indicator 13 Wire terminals 14 Case holder 15 RS232 terminal Terminal connections Do not input an over voltage to the AC input terminals 1 Input the ACV power 90 to 260 ACV to T1 T2 2 Connect the C...

Страница 5: ...3 Press the Function button once until the ft min indicator is on The display will show the ft min value 4 Under the surface speed measurement the PV indicator will also light 5 To calculate m min Tot...

Страница 6: ...ue Setting 1 After setting the Low Limit value press the Set button twice the display will show HILt the meter is now ready for the humidity High Limit value setting 2 Use the button and the to adjust...

Страница 7: ...on press the Set button twice the display will show dIA now the meter is ready for the Roller diameter value setting 2 Use the button and the button to adjust the Roller diameter value in the unit of...

Страница 8: ...relay will be On when measuring value up to 100 The alarm relay will turn Off again when measuring value down to 95 2 The alarm relay will be On when measuring value down to 20 The alarm relay will tu...

Страница 9: ...Power Supply DC 12 V 50 mA max Data Output RS 232 PC serial interface Operating Temperature 32 to 122 F 0 to 50 C Operating Humidity Less than 80 R H Power Supply 90 to 260 ACV 50 60 Hz Power Consumpt...

Страница 10: ...dity 35 to 95 RH Wire Dimension 4 7 mm Dia x 2 m x 3 cores Cable length 6 ft 1 8 meters 461957 Photoelectric Sensor Specifications Range Up to 6000 RPM 100 Hz Power 12 24VDC 10 Consumption 40mA max Re...