Specifications

General Specifications

Circuit

Exclusive one-chip LSI circuit with crystal time base

Display

4-digit (10,000 count; 0 to 9999) LED display 

Measurement unit

RPM (revolutions or rotations per minute) is the speed of the 
moving device under test which equals the FPM rate (strobe 
flashes per minute)

Operating Temperature

32 to 122

o

F (0 to 50

o

C)

Operating Humidity

< 80% RH

Power Supply

110VAC (461830) or 220VAC (461831) 50/60Hz  ±10%

Power Consumption

<25 watts @ 115V

Weight

1kg (2.2 lbs.)

Dimensions

21 x 12 x 12cm (8.3 x 4.8 x 4.8")

Housing construction

Impact resistant plastic with plastic lens and mirrored reflectors 

Electrical Specifications

Measurement Range

100 to 10,000 RPM/FPM

Resolution

0.1 (<1000 RPM/FPM)
1 (1000 to 9999 RPM/FPM)
10 (10,000 RPM/FPM)

Accuracy

± (0.05% + 1 digits)

Sampling Time

1 second

Strobe Flash adjust range

LOW: 100 to 1,000 RPM/FPM
HIGH: 1000 to 10,000 RPM/FPM

Strobe Flash tube type

Xenon lamp  

Strobe Flash duration

60 to 1000 microseconds

Strobe Flash Energy

4 Watt-Seconds (Joules)

Strobe Beam Angle

80

o

Strobe Flash Color

White 6500

o

K

Notes: 

Replace the Xenon lamp when readings appear irregular. To prolong the Xenon lamp life and 

ensure safe operation, please adhere to the following recommendations.

A 30-minute use limit < 3000rpm and 5-minute use limit > 3000rpm exists. Do not use the 
instrument for periods longer than specified otherwise damage to the instrument may result.
Always permit a 10-minute cool-down between cycles.
Do not touch the Xenon flash tube.

www.

.com

[email protected]

1.800.561.8187

Содержание 461830

Страница 1: ...User Manual Digital Stroboscope Tachometer Model 461830 and Model 461831 www com information itm com 1 800 561 8187 ...

Страница 2: ... provide years of reliable service Safety This symbol adjacent to another symbol or terminal indicates the user must refer to the manual for further information This symbol adjacent to a terminal indicates that under normal use hazardous voltages may be present WARNING Do not look directly at the Strobe eflector WARNING This device causes moving objects to appear still Take precautions against acc...

Страница 3: ...100 to 10 000 RPM FPM Resolution 0 1 1000 RPM FPM 1 1000 to 9999 RPM FPM 10 10 000 RPM FPM Accuracy 0 05 1 digits Sampling Time 1 second Strobe Flash adjust range LOW 100 to 1 000 RPM FPM HIGH 1000 to 10 000 RPM FPM Strobe Flash tube type Xenon lamp Strobe Flash duration 60 to 1000 microseconds Strobe Flash Energy 4 Watt Seconds Joules Strobe Beam Angle 80o Strobe Flash Color White 6500o K Notes R...

Страница 4: ...r Description 1 Xenon lamp 2 LED Display 3 Grip handle 4 COARSE adjust knob 5 FINE adjust knob 6 Power ON OFF switch 7 Range Select Switch 8 AC power cord and jack www com information itm com 1 800 561 8187 ...

Страница 5: ...ange is used for measurements below 1 000 RPM The HIGH range is used for measurements above 1 000 RPM Visually inspecting a moving object stop motion When the speed of the moving object matches the flash rate of the stroboscope the moving object appears still Measure the speed of a moving object as described in the previous sections to obtain a stop motion Once stop motion is achieved the FINE adj...

Страница 6: ...ce of tape The illustrations below represent several possible images that would appear when the strobe beam is pointed to the shaft If more than one mark appears as i The bold column column 2 shows the actual speed of the shaft Column 1 shows a harmonic between Column 2 in bold Shaft speed 1000rpm 1000rpm 1000rpm 1000rpm 1000rpm Strobe flash rate 500rpm 1000rpm 2000rpm 3000rpm 4000rpm Visible mark...

Отзывы: