Extech Instruments 4465CF Скачать руководство пользователя страница 6

Model 446580 Version 2.0 June 2004 

6

Datalogging One Reading (Manual Logging) with the Model 446580 

1.  Set the TEMP-%RH-RECORD switch to the RECORD position 

2.  Press the RECORD-ERASE button once. The RECORD display icon will flash briefly 

on the LCD. 

3.  One reading is now placed in the internal memory of the meter. 

Datalogging Continuously (Automatic Logging) 

1.  Set the TEMP-%RH-RECORD switch to the RECORD position 

2.  Press and hold the RECORD-ERASE button for 3 seconds. The RECORD display icon 

will flash periodically as readings are stored at the programmed sampling interval. To 
change the sampling interval, refer to SETTING THE DATALOGGER RECORDING 
INTERVAL section later in this manual. 

3.  To stop recording, momentarily press the RECORD-ERASE button. Note that when 

recording is started again, the new data points will be stored in a new ‘set’. Data sets 
are discussed in the remaining sections. 

Erase Stored Data using the meter’s RECORD-ERASE button 

1.  With the meter turned off, press and hold the RECORD-ERASE button while turning 

the meter on. 

2. When 

the

 DEL

 display icon flashes on the LCD, release the RECORD-ERASE button. 

All data is now cleared. 

3.  Note that data can also be erased via software as explained later in this manual. 

Download data from the Model 446580 

1.  With the meter connected to the PC and with the supplied software running, select 

MEMORY from the OPTION menu in the PANEL software window. The LOGGER 
window will open (see LOGGER window description). 

2.  To initiate the data transfer, click on the TIME OF RECORDING button. 

3.  The data will appear in groups or ‘sets’. Each set represents a separate recording 

session. 

4.  To view the data in a particular set, click on the set number and then click on the 

SHOW DATA button. The REC LIST software will open and the individual data points 
within the selected set will appear.  

Logger Software Window Description 

1.  Total and remaining memory fields – 

Total memory is 32K 

2.  Current Date (YY:MM:DD) and Time 

(HH:MM:SS) 

3.  Number of data sets currently in the 

meter 

4.  Number of data points in the currently 

selected data set 

5.  Press to show the data points 

contained in the currently selected 
data set 

6.  User selectable 5-digit reference 

number 

7.  Current sampling rate for the 

Datalogging function not the Data 
Acquisition function 

8.  Press TIME OF RECORDING to download the data sets contained in the meter to the 

PC 

9.  List of downloaded data sets 
10. Data Set numbers (click on a number to select a set) 

1

2

3

4

5

6

7
8

 9

10

Содержание 4465CF

Страница 1: ...s on your purchase of the Extech 4465CF or 446580 Hygro Thermometer The Extech Hygro Thermometers measure and display temperature and relative humidity The 446580 has a PC interface and built in datalogging capabilities Careful use of these meters will provide years of reliable service ...

Страница 2: ...e for any direct indirect incidental or consequential damages Extech s total liability is limited to repair or replacement of the product The warranty set forth above is inclusive and no other warranty whether written or oral is expressed or implied Specifications General Specifications Display Multi function 3 digit 2000 count LCD display Measurement Relative Humidity RH and Temperature C F Data ...

Страница 3: ...ripod mount is located at the rear of the meter 5 Humidity changes take time 3 to 5 minutes to stabilize Please allow time for the display to settle 6 When the low battery icon flashes on the LCD replace the 9V battery Displayed Readings The Model 4465CF displays humidity or temperature readings in the center of the LCD depending upon the position of the TEMP RH switch The Model 446580 displays bo...

Страница 4: ... takes readings while connected to the PC The readings are taken displayed and stored all at the same time These two modes are discussed in the subsequent sections Datalogging Mode The meter can log up to 7000 readings that can later be transferred to a PC The benefit is that the meter can record remotely without having to be connected to a PC The supplied Windows TM software allows the user to tr...

Страница 5: ...data filename and location for data acquisition 8 PC COM port status COM1 or COM2 will appear if communication is active NO COM will appear if communication is not active Setting the Meter s Real Time Clock 1 Click OPTION in the PANEL software window and select SYSTEM TIME SET 2 The current PC system time and date will now be transferred to the meter 3 When data is logged the time and date informa...

Страница 6: ...now cleared 3 Note that data can also be erased via software as explained later in this manual Download data from the Model 446580 1 With the meter connected to the PC and with the supplied software running select MEMORY from the OPTION menu in the PANEL software window The LOGGER window will open see LOGGER window description 2 To initiate the data transfer click on the TIME OF RECORDING button 3...

Страница 7: ...he meter connected to the PC clear the entire contents of the meter s internal memory by selecting ERASE from the OPTION menu in the PANEL software window Data Acquisition Mode 1 With the meter connected to the PC and the supplied software up and running select SAVE AS from the FILE menu in the PANEL software window 2 A window will appear prompting for a filename and location Select a filename and...

Страница 8: ...reviously saved data file The Text Import Wizard will open 5 Step 1 of 3 in the Wizard Choose DELIMITED 6 Click NEXT 7 Step 2 of 3 see diagram Under DELIMITERS check the TAB box type a quotation mark in the OTHER box and select NONE in the TEXT QUALIFIER field 8 Click NEXT 9 Step 3 of 3 Click FINISH The data file will now open You may wish to save the file as an ExcelTM file rather than a data fil...