background image

42280-EU-EN-V4.4-12/11 

Operation 

Important Note before starting 

This meter relies on firm button presses to operate correctly. Be sure to press firmly and hold the 
button for as long as directed in the instructions. 

Meter Power 

1.  The meter is powered by four (4) ‘AA’ 1.5V batteries or the 117V AC adaptor. 
2.  When the batteries are installed or the adaptor is connected to an AC power source, 

momentarily press the START-STOP button to turn the meter ON. 

3.  Press the START-STOP button again to turn the meter OFF. 

Viewing the displayed readings 

1.  Normally, the top line indicates temperature in degrees C or F. Use the MODE button to switch 

between degrees C and degrees F. 

2.  Press and hold the MODE for at least 2 seconds. This will change the top display to Dew Point 

temperature. The ‘DP’ icon will appear on the LCD when in Dew Point mode. Press and hold the 
MODE button for at least 2 seconds to return the top display to the normal temperature display 
mode. 

3.  The middle line displays Relative Humidity in %. 
4.  The bottom line automatically alternates between Time and Date displays. 
5.  If the ALM status LED illuminates and the display flashes, one of the Alarm limits has been 

reached. Program the High and Low Temperature/Humidity limits in Programming parameter P5 
(detailed later in this user guide). 

Datalogger Basics 

The Model 42280 has a built-in Datalogger that can store up to 8000 temperature and 8000 
humidity readings. Readings can be stored in the meter and transferred at a later time to a PC. The 
meter can also display real-time readings on a connected PC; in other words, the PC can display 
readings at the instant the readings are taken. 
The meter must be configured before datalogging can be attempted. Parameters such as Real Time 
Clock and Datalogger Sample Rate must be programmed before datalogging can begin. It is 
strongly recommended that the user take advantage of the supplied software to configure the meter. 
Instructions for manually configuring the meter are provided below; however configuring the meter 
via software is very convenient. 
Basic instructions for connecting the meter to a PC and getting started with the supplied software 
are provided later in this guide. Detailed instructions regarding the supplied software are provided in 
a separate manual included on the supplied CD-ROM and the HELP utility in the software program. 

Содержание 42280

Страница 1: ...User Guide Temperature and Humidity Datalogger Model 42280...

Страница 2: ...meter is shipped fully tested and calibrated and with proper use will provide years of reliable service Material list Supplied Materials Meter User Guide USB cable Program CD Four 4 batteries 1 5V AA...

Страница 3: ...display 7 RECORD status LED 8 USB port 9 AC Adaptor jack 10 Datalogger START STOP button 11 MODE button 12 SET button 13 Up Arrow button 14 Down Arrow button 15 Tripod mount jack Notes The battery com...

Страница 4: ...5 If the ALM status LED illuminates and the display flashes one of the Alarm limits has been reached Program the High and Low Temperature Humidity limits in Programming parameter P5 detailed later in...

Страница 5: ...ample Rate set the datalogging interval from 1 second up to 12 hours P5 Alarm Mode set High and Low Temperature Humidity limits P6 Real Time Clock set the meter s internal date and time clock Programm...

Страница 6: ...t and diagram below a rEp Repeat Start mode Logger starts once readings are downloaded to PC b hEy Keypad Start Datalogging begins after the START STOP button is held for 2 seconds c imm Immediate Sta...

Страница 7: ...arrow buttons to set month 7 Press the SET button again 8 Use the up down arrow buttons to set the day 9 Press the SET button again 10 Use up down buttons to set the hours 11 Press the SET button aga...

Страница 8: ...ing Mode P5 High and Low Alarms 1 Press the SET button to access the setup mode 2 Use the arrow buttons to select parameter P5 3 Press the SET button again 4 Use the up down arrow buttons to set the H...

Страница 9: ...button again 8 Use the up down arrow buttons to set the day 9 Press the SET button again 10 Use the up down arrow buttons to set the hours 11 Press the SET button again 12 Use the up down arrow butto...

Страница 10: ...g 4 To stop recording press and hold the START STOP button for at least 2 seconds The REC status light will stop blinking Starting the Datalogger in Schedule Mode 1 In Schedule Mode the meter begins r...

Страница 11: ...These are described in some detail in the separate software manual and the software HELP utility on the supplied CD ROM Remember to press OK after changing a setting to ensure that the software proces...

Страница 12: ...the 75 Calibration Reference bottle 5 Press and hold the START STOP button for at least 2 seconds to enter the 75 Calibration mode The display 75 3 will begin to flash on the display 6 Approximately...

Страница 13: ...to 70 o C 4 to 144 o F Resolution 0 1 o C o F Accuracy Temp 1 0 F 0 6 C from 0 to 50 C 32 to 122 F 2 0 F 1 2 C outside of this range Humidity 3 from 10 to 90 5 outside of this range Datalogger memory...

Страница 14: ...4 E02 and E03 combined error E11 CAL error recalibration required E32 IC read write error Return unit for repair E33 Circuit Error Return unit for repair Battery Replacement You as the end user are le...

Отзывы: