CONTACT TEMPERATURE MEASUREMENTS
1. Set the function switch to the black Type K ºC or ºF position.
2. Insert the Temperature Probe into the input jacks, making sure to observe the correct
polarity.
3. Touch the Temperature Probe head to the part whose temperature you wish to measure.
Keep the probe touching the part under test until the reading stabilizes (about 30
seconds).
4. Read the temperature in the display.
Note:
The temperature probe is fitted with a type K mini connector. A mini
connector to banana connector adaptor is supplied for connection to
the input banana jacks.