background image

407907-EN v1.5   10/13 

Introduction 

Congratulations  on  your  purchase  of  the  Heavy  Duty  Extech  407907  RTD  Thermometer  which 
offers  high  precision  and  selectable  0.1

o

  and  0.01

o

  resolution.  The  LCD  display  provides  low 

battery  and  overload  indication.  Selectable  temperature  units  °C  &  °F  provides  measurement 
versatility. This meter is shipped fully tested and calibrated and with proper use will provide years 
of reliable service. 

 

Specifications 

General Specifications 

 

Display 

 

4-1/2 digit (20,000 count) LCD display with over-range 
and low battery indication

 

Measurement

 

Temperature (selectable °C & °F units)

 

Data Hold

 

Freezes displayed reading

 

RTD Probes (sold separately)

 

4-wire platinum 100

 RTD; 

0.00385 alpha coefficient (meet DIN IEC 751)

 

RTD probe jack 

Proprietary 4 pin circular connector 
(uses Extech RTD probes 

– sold separately) 

Sampling Time

 

Approximately 0.4 seconds

 

Memory record/recall 

Meter stores Maximum and Minimum readings 

Data Output 

RS-232 PC Interface 

Operating  conditions

 

Temperature: 32°F to 122°F (0°C to 50°C); RH: < 80%

 

Power Supply

 

9V battery

 

Power consumption

 

15 mA DC (approx.)

 

Weight      

 

0.53 lbs. (242g)

 

Dimensions   

 

7.1 x 2.8 x 1.3” (180 x 72 x 32 mm)

 

Range Specifications 

Temperature Ranges

 

Resolution

 

Accuracy (% of reading) 

o

F  -199.99

o

 to 392.00

F

 

0.01

o

 F

 

± (0.1% + 0.4

o

F) * 

 392.0

o

 to 1562.0

o

0.1

o

C  -199.99

o

 to 199.00

o

C

 

0.01

o

 C

 

± (0.1% + 0.2

o

C) * 

200.0

o

 to 850.0

o

0.1

* Probe accuracy is additional

 

Содержание 407907

Страница 1: ...User s Manual RTD Thermometer Model 407907 Shown with RTD probe Probe sold separately ...

Страница 2: ...nits Data Hold Freezes displayed reading RTD Probes sold separately 4 wire platinum 100 RTD 0 00385 alpha coefficient meet DIN IEC 751 RTD probe jack Proprietary 4 pin circular connector uses Extech RTD probes sold separately Sampling Time Approximately 0 4 seconds Memory record recall Meter stores Maximum and Minimum readings Data Output RS 232 PC Interface Operating conditions Temperature 32 F t...

Страница 3: ...ications shown earlier in this manual to determine the best resolution for the measurement range of a given application Taking measurements Once the meter has been setup and a probe has been inserted in the jack at the top of the meter place the temperature probe in the area under test Give the meter several seconds to stabilize Read the temperature measurement on the LCD If dashes appear on the d...

Страница 4: ...7001 and enables the user to store readings on a PC For more information contact Extech or refer to the manual accompanying the software for details Battery Replacement The low battery indicator battery symbol appears on the LCD when the 9V battery needs replacing Reliable readings can be obtained for several hours after the first appearance of the low battery indicator To replace the battery 1 Re...

Страница 5: ... or consequential damages FLIR s total liability is limited to repair or replacement of the product The warranty set forth above is inclusive and no other warranty whether written or oral is expressed or implied Calibration Repair and Customer Care Services FLIR Systems Inc offers repair and calibration services for the Extech Instruments products we sell NIST certification for most products is al...

Отзывы: