background image

Model 407777 Version 2.2 Jan 04 

Wallboard Moisture Measurements 

Unlike wood types which have known densities, wallboard does not. Consequently it is not 
possible to get an absolute moisture content reading. 

The following procedure can be used to make relative or comparative measurements of 
the moisture content in wallboard. 

1.  Turn ON the meter. 

2.  Select Material Group 1 by pressing the Material Select button. 

3.  Insert the sensor's test pins into a known dry area of wallboard. Insertion should be to 

at least a 0.08" (2mm) depth. The meter display will now indicate moisture content in 
%. Note this ‘dry’ reading. 

4.  Insert the sensor's test pins into the wallboard under test. Insertion should be to at 

least a 0.08" (2mm) depth. The meter display will now indicate moisture content in %. 
Note this ‘moist’ reading. 

5.  Compare the ‘dry’ wallboard reading with the ‘moist’ wallboard reading to determine the 

moisture content of the wallboard area under test. 

Temperature Compensation 

This meter is calibrated for use at ambient temperature: 68

o

F (20

o

C). When the 

temperature is above or below this value, manual temperature compensation should be 
performed to maintain meter measurement accuracy. Follow these steps: 

1. 

Check that the RECORD function is not engaged (‘REC’ display icon is off). 

2. 

Use the TEMPERATURE ADJUST buttons to increase (left button) or decrease (right 

button) the temperature display to match the new temperature (in 

o

C). The 

temperature is adjustable in 1 degree steps. 

3. 

The value will be stored after 4 seconds. Temperature compensation adjustments are 

not stored in memory when the meter is turned OFF however. 

Data Hold 

To freeze the LCD display reading, press the HOLD key. The 'DH' icon will appear on the 
LCD. Press the HOLD key again to return to normal operation (the 'H' hold icon will switch 
OFF). 

Maximum (MAX) and Minimum (MIN) Record and Recall 

To keep track of the highest (MAX) and lowest (MIN) measurements, follow the procedure 
below: 

1.  Press the RECORD button to begin tracking the highest and lowest readings. The REC 

display icon will appear on the LCD. 

2.  Press the RECALL key when it is desired to view the highest reading since the 

RECORD button was pressed. The MAX icon will appear on the display and the 
reading shown will be the highest reading encountered since the RECORD key was 
pressed. 

3.  Press the RECALL key again to view the lowest reading (MIN). 

4.  To exit this mode of operation, press the RECORD key again. The REC, MAX, and 

MIN icons will switch off. 

Содержание 407777

Страница 1: ...n Congratulations on your purchase of the Extech 407777 Wood Moisture Meter This meter measures the moisture content of wood as a percentage Measurements are made using the supplied remote intrusive sensor Careful use of this meter will provide years of reliable service ...

Страница 2: ...ial damages Extech s total liability is limited to repair or replacement of the product The warranty set forth above is inclusive and no other warranty whether written or oral is expressed or implied Specifications General Specifications Circuit Custom one chip LSI microprocessor circuit Display Dual function 2000 count 0 to 1999 LCD display Measurement Range 9 to 30 Moisture Content Memory Table ...

Страница 3: ... through 9 see Table in the Appendix Record Track the highest MAX and lowest MIN readings Recall Review the MAX and MIN readings Calibration and Used to calibrate the meter refer to the calibration section Temperature Adjust Used for temperature compensation function refer to temperature compensation section in this manual 5 Battery compartment back Remove the rubber protective holster to access t...

Страница 4: ...he Appendix later in this manual Select group 1 through 9 for general woods or Group 9 for chipboard 3 Insert the sensor s test pins into the wood under test 4 Insertion should be to at least a 0 08 2mm depth for highest accuracy If this is not possible carefully insert the test pins as far as possible without using undue force 5 The meter display will now indicate moisture content in 6 If the moi...

Страница 5: ... performed to maintain meter measurement accuracy Follow these steps 1 Check that the RECORD function is not engaged REC display icon is off 2 Use the TEMPERATURE ADJUST buttons to increase left button or decrease right button the temperature display to match the new temperature in o C The temperature is adjustable in 1 degree steps 3 The value will be stored after 4 seconds Temperature compensati...

Страница 6: ...Calibration Calibration Verification 1 Ensure that the RECORD function is not engaged REC icon is not on the LCD 2 Select Material Group 1 using the Material Select button 3 Press and hold both the CALIBRATION and the buttons 4 The display will begin to count down from 5 to 1 5 If the meter s existing calibration is correct the LCD will display good 6 If the meter s existing calibration is incorre...

Страница 7: ...bank 2 Odoko 4 Silky Oak Australian 3 Birch Yellow 4 Jarrah 3 Okwen 2 Spruce Norway European 3 Bisselon 4 Jelutong 3 Olive E African 2 Spruce Sitka 3 Bitterwood 5 Kapur 1 Olivillo 6 Sterculia Brown 1 Blackbutt 3 Karri 1 Opepe 7 Stringybar Yellow 3 Bosquiea 1 Kauri New Zealand 4 Padang 1 Stringybark Messmate 3 Boxwood Maracaibo 1 Kauri Queensland 8 Padauk African 5 Sycamore 5 Cahoma 1 Keruing 5 Pan...

Страница 8: ...calibration services for the products we sell Extech also provides NIST certification for most products Call the Customer Service Department for information on calibration services available for this product Extech recommends that annual calibrations be performed to verify meter performance and accuracy Copyright 2004 Extech Instruments Corporation All rights reserved including the right of reprod...