Operation 

1. Power the meter by moving the RANGE switch to the LO or HI position. The meter will 

begin displaying sound levels. If the LCD does not display, check that the battery is 
good. 

2. Place the meter on a tripod or hold the meter in hand facing the microphone toward the 

source of the sound to be measured. Note that the tripod mount is on the back of meter. 

3. View the measurement on the meter’s LCD. An indication of ‘OVER’ means that the 

measurement is out of range. Select another measurement range in the event of an 
over-range condition. 

‘A’ and ‘C’ Frequency Weighting 

Use the FUNCT (function) switch to select ‘A’ or ‘C’ frequency weighting. Use ‘A’ weighting 
to have the meter simulate the response of the human ear (the human ear boosts and cuts 
sound levels at specific points over the frequency spectrum). ‘A’ weighting is used for 
environmental measurements, OSHA regulatory testing, law enforcement, and workplace 
design. Select ‘C’ weighting for flat response measurements (no boosting or dampening 
across the frequency spectrum). ‘C’ weighting is suitable for the operational maintenance 
and analysis of machinery, motors, pumps, engines, etc.   

FAST/SLOW Response Time 

Use the RESPONSE switch to select FAST (125 ms) or SLOW (1 second) response time. 
The application at hand (and any directives or standards) will dictate which response to 
select. For example, most hearing conservation or OSHA related testing is done using 
SLOW mode and ‘A’ weighting. 

MAX HOLD 

In this mode, the meter only updates the LCD when a higher reading than the one 
presently on the display is detected. Select MAX HOLD using the RESPONSE switch. The 
LCD shows ‘MAX HOLD’ in this mode. Press RESET to reset the MAX HOLD reading. 

Analog Outputs 

The meter includes an AC and a DC analog output for use with chart recorders, 
dataloggers, etc. The AC output is 0.65V rms full scale and the DC output is 10mV per dB. 
The 3.5mm output jack is located on the right side of the instrument. Use a stereo mini-
plug as shown in the diagram below to connect the meter to a datalogger or other recorder. 

 
 
 
 

 
 
 

Battery Replacement 

 
When the low battery message appears on the LCD replace the 9V battery as soon as 
possible. The battery compartment cover resides at the bottom, rear of the meter. Slide 
the battery compartment cover off, change the battery, and replace the compartment 
cover. 

Calibration Check 

This meter provides a built-in calibration adjustment. The calibration adjustment 
potentiometer is located on the front panel beneath the FUNCT switch. Put the FUNCT 
switch to the CAL 94dB position and adjust the potentiometer for a display of exactly 
94dB.  For calibration with an external sound level calibrator, refer to the instructions 
accompanying the calibrator. 

Tip: AC Output 

Ring: DC Output 

Sleeve: Ground 

Stereo plug 

Содержание 407735

Страница 1: ...tal Sound Level Meter Model 407735 Introduction Congratulations on your purchase of the Extech Model 407735 Digital Sound Level Meter This professional meter with proper care will provide years of safe reliable service ...

Страница 2: ...ity 10 to 90 RH Dimensions weight 9 45 x 2 68 x 1 240 x 68 x 25mm 6 75oz 210g Meter Description 1 Microphone 2 LCD display 3 POWER OFF RANGE select switch 4 RESPONSE HOLD select switch 5 A C weighting and Calibration switch 6 Calibration adjust screw for 94dB 7 Reset key resets max hold reading 8 AC DC analog output 3 5mm phone jack 9 Battery compartment and Tripod mount are located on back of met...

Страница 3: ...y directives or standards will dictate which response to select For example most hearing conservation or OSHA related testing is done using SLOW mode and A weighting MAX HOLD In this mode the meter only updates the LCD when a higher reading than the one presently on the display is detected Select MAX HOLD using the RESPONSE switch The LCD shows MAX HOLD in this mode Press RESET to reset the MAX HO...

Страница 4: ...r unauthorized modification Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct indirect incidental or consequential damages Extech s total liability is limited to repair or replacement of the product The warranty set forth above is inclusive and no other warranty whether written or oral is expressed or imp...

Отзывы: