5.11 Diode Measurements 

 

Warning:

 Before attempting any in-circuit measurements remove power from the circuit 

under test and discharge any capacitors. 

 

1. Set the Rotary Selector switch to the diode/continuity function (diode symbol). 

2. Connect the black test lead to the COM terminal and red test lead to the V/

/uF 

terminal. 

3. Connect the red test lead to the anode side of the diode, and the black test lead to the 

cathode side of the diode under test. 

4. Read the forward voltage value on the LCD. 

5. If the test leads are connected in reverse of step 3 above, the meter should read open 

circuit voltage if the diode is in working condition. 

 

 

5.12 Peak Hold / Data Hold Modes 

 

1. Peak Hold allows the meter to capture fast voltage or current peaks. 

2. Data Hold freezes the reading on the display when the Data Hold key is pressed. 

3. Set the Rotary Selector switch to the AC Voltage or Current function position for Peak 

Hold measurements. For Data Hold, set the switch to any function position. 

4. Set the clamp meter to the Peak Hold or Data Hold mode by pressing the Peak Hold or 

Data Hold key once. 

5. The display will now indicate “P” for Peak Hold or ‘H’ for Data Hold. 

6. For Peak Hold, the display will show the maximum peak of a measured signal surge. For 

example, in-rush current during a motor start-up can be easily detected using Peak Hold 

mode. For Data Hold, the LCD reading is frozen. 

7. To return to normal operation press the Peak or Data Hold key again. 

 

 

6. MAINTENANCE 

 6.1 Battery Replacement 

Warning: 

To prevent electrical shock or hazard, remove power to the meter and remove 

the test leads before removing back cover.

 

1.  The meter displays ‘BT’ when the battery voltage falls critically low. Replace battery as 

soon as possible when this icon appears on the meter LCD. 

2.  Set the rotary switch to the OFF position and remove all test leads. 

3.  Unscrew the three back cover screws to access the battery compartment. Note that the 

screw nearest the meter jaw is a shorter machined screw. Be sure to install the same 

screws in the same screw holes after replacing battery. 

4.  Replace battery and reinstall back cover. 

 

6.2 Cleaning 
Warning: 

To avoid electrical shock or damage to the meter, do not allow water or other 

liquids to enter the meter case. Remember to remove power and test leads before 

opening meter case.

 

Periodically wipe the case with a damp cloth and mild detergent. Do not use abrasives or 

solvents. 
 

 

 

 

 

Содержание 380973

Страница 1: ...nusoidal waveform measurements Peak Hold and Data Hold Selectable temperature measurement units Frequency measurements using the current jaws or using the test leads 1 INTRODUCTION Congratulations on your purchase of Extech s 380973 True RMS AC Clamp on DMM This professional meter with proper care will provide years of safe reliable service ...

Страница 2: ...1MΩ DC Voltage 600V 1V 0 75 2d 660V rms input imp 1MΩ Resistance 4KΩ 0 001kΩ 1 0 5d 660V rms 3 2VDC open cir Frequency 4KHz clamp test 1Hz 0 5 rdg 5d 800A sensitiv 5A 4KHz lead test 1Hz 0 5 rdg 5d 660V sensitiv 1V Capacitance 2000uF 1uF 3 5d 250V rms Type K Therm 20 to 300o C 1o C 2 3o C 300 to 1200o C 1o C 3 5 2o C 4 to 2192o F 1o F 3 8o F 660 Vrms Continuity Buzzer 40 ohms oc V 3V sc A 0 8mA 660...

Страница 3: ...6 Data Hold key Press to activate press again to deactivate 7 Rotary selector switch Powers meter while selecting function and range 8 Negative input terminal Black test lead connection COM 9 Positive input terminal Red test lead connection for voltage resistance frequency capacitance temperature diode and continuity tests 10 Temperature units select key Press to select desired units 4 INTERNATION...

Страница 4: ...rmer jaw around one of the conductors under test Open the jaw via the jaw trigger 3 Ensure that the clamp closes completely around the conductor 3 Read the displayed measurement value on the display 5 4 DC Voltage Measurements Warning Maximum DC input voltage is 600V To avoid electrical shock or damage to the instrument do not attempt to measure any voltage exceeding this limit 1 Set the Rotary Se...

Страница 5: ... to the uF function 2 Remove at least one leg of a capacitor from its circuit before testing 3 Connect the black test lead to the COM terminal and red test lead to the V Ω uF terminal and connect the other ends of the test leads to the circuit component or other device under test 4 If measuring a polarity sensitive electrolytic capacitor touch red test lead to the positive side of the cap and the ...

Страница 6: ...nce 5 The display will now indicate P for Peak Hold or H for Data Hold 6 For Peak Hold the display will show the maximum peak of a measured signal surge For example in rush current during a motor start up can be easily detected using Peak Hold mode For Data Hold the LCD reading is frozen 7 To return to normal operation press the Peak or Data Hold key again 6 MAINTENANCE 6 1 Battery Replacement War...

Страница 7: ...440 for authorization A Return Authorization RA number must be issued before any product is returned to Extech The sender is responsible for shipping charges freight insurance and proper packaging to prevent damage in transit This warranty does not apply to defects resulting from action of the user such as misuse improper wiring operation outside of specification improper maintenance or repair or ...

Отзывы: