background image

 

Tare Operation 

Tare allows you to weigh samples with the samples still in a container. The container weight becomes 

the “tare” weight and is subtracted from each reading so that only the product sample weight is 

displayed. 

1.  Place the container on the platform. 
2.  Press the TARE key and the display will read zero. 
3.  Remove the container from the platform. The display will indicate a negative reading. The 

reading will be negative in the amount of the TARE weight. 

4.  When objects are weighed, the reading will be the total weight minus the TARE value. The 

NET down-arrow indicator will appear informing the user that a Tare weight is in memory. 

5.  To remove the previous Tare value from memory, remove all weight from the Scale platform 

and press the TARE key so that the NET indicator turns off and the display returns to zero. 

Sample Piece Counting 

The scale allows the user to place a known number of samples on the platform and have the scale 

display Piece Count or Total Piece Weight 

1.  Place 10, 20, 50, or 100 sample pieces on the Scale platform. The total weight will display in 

lbs or kg as selected using the UNITS key. 

2.  Press the SMPL key to permit the Scale to begin scrolling the numbers 10, 20, 50, and 100 on 

the display. Set the number of sample pieces by pressing the SMPL key firmly when the 

number of samples matches the display. 

3.  Now when any number of pieces of the same weight are placed on the platform, the LCD will 

display accurate Piece Count.  

Auto Power OFF Configuration 

The Scale is equipped with an Auto Power OFF feature that powers the meter down after a specified 

period of time. To defeat or otherwise configure this feature, follow these steps. 

1.  With the meter power off, press and hold any key while powering the unit. 
2.  Release the key once the Scale powers up. 
3.  Press the FUNC key. The display will show PO = 0, 1, 2, 3, or 4 depending upon present 

setup. 

4.  Press the FUNC key until the desire value scrolls up on the LCD 
5.  Use the Table below to select the desired action. 
6.  Press the SMPL key to store the entry into non-volatile memory. 

 
Program Step 

 Action 

PO = 0  

 

Auto Power OFF is defeated 

PO = 1  

 

Auto Power OFF after 5 mins 

PO = 2  

 

Auto Power OFF after 10 mins 

PO = 3 

 

Auto Power OFF after 20 mins. 

PO = 4  

 

Auto Power OFF after 30 mins. 

  

 
 

Содержание 160276

Страница 1: ...User s Manual High Capacity Bench top Counting Scale Model 160276...

Страница 2: ...horized modification Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct indirect incidental or consequentia...

Страница 3: ...17AC adapter recharger Proper use and care of this device will yield years of reliable service Specifications Display LCD Display with 0 8 character height LCD status arrows Display for low battery ze...

Страница 4: ...by an internal rechargeable battery The supplied AC adapter is used for recharging When the LOBATT display arrow appears connect the AC adapter recharger to the scale then plug the adapter into a 110...

Страница 5: ...ation of Programming Keys ON TARE Press to power the Scale from a power OFF state If the Scale is already powered pressing the TARE key enters the gross weight on the Scale as the TARE weight OFF Pres...

Страница 6: ...on the Scale platform The total weight will display in lbs or kg as selected using the UNITS key 2 Press the SMPL key to permit the Scale to begin scrolling the numbers 10 20 50 and 100 on the displa...

Страница 7: ...row indicator appears above the word LoBatt connect the AC Adapter Recharger to the Scale behind the LCD display Then plug into a 117VAC 50 60Hz outlet to begin charging When the battery is fully char...

Страница 8: ...8 Notes...

Отзывы: