EX-6114
4. Hardware Installation
2. Now use an Ethernet cable and connect it to the RJ45 port of the EX-6114 and the other end to a
PC or a switch.
3. Now connect your serial devices to the 9 pin D-SUB connectors of the EX-6114.
4. Now connect the 5V power supply which is included in the extend of delivery to the 5V socket
provided for this purpose on the EX-6114. Wait about 25-30 seconds until the status LED starts to
blink. As soon as this LED flashes, the device is ready for operation.
© Copyright 2021 by EXSYS Vertriebs GmbH. All Rights Reserved
5. Configuration of the Device Server
Factory Settings:
The EX-6114 is delivered with the following factory settings:
Login User Name:
admin
Password:
system
IP Address:
DHCP (Assigned Automatically)
Network Operation Mode:
VCOM Mode
Serial Interface:
RS-232
If you want to reset the EX-6114 to "Factory Settings", then press and hold the reset button for
approx. 3-5 seconds. The status LED goes out and starts flashing again a few seconds later.
Please note that the settings after the reset are not identical to the factory settings! When you have
reset the EX-6114 to "Factory Settings", you will have the following settings in the device:
Login User Name:
admin
Password:
system
IP Address:
Static 192.168.2.1
Network Operation Mode:
TCP Server Mode
Serial Interface:
RS-232