background image

MODELS • VCDD010

I

• VCDD015

I

VCDD020

I

• VCDD025

I

• VCDD030

I

Page 2

TYPICAL INSTALLATION

TYPICAL INSTALLATION

MOUNTING (New Frame Construction)

Factory-shipped unit installed in new construction.

MOUNTING (Existing Frame Construction)

Factory-shipped unit installed in existing construction.

* VCDD010

I

& VCDD015

I

use 6” round duct.

VCDD020

I

, VCDD025

I

& VCDD030

I

use 8” round duct.

Two ways to connect ductwork to a factory-shipped unit.

* VCDD010

I

& VCDD015

I

use 6” round duct.

VCDD020

I

, VCDD025

I

& VCDD030

I

use 8” round duct.

IMPORTANT:

Remove shipping tape from damper

Remove the shipping tape from the damper flap and make sure
that damper flap opens and closes freely inside the ductwork.
Use duct tape to make ductwork connections secure and air-tight.

Remove shipping ring from blower inlet

Remove the shipping ring from the blower inlet before
operating the ventilator.

WIRING

Ventilator can be wired from outside of housing.

Use UL approved connectors to wire per local codes.

DUCTING (Straight-Through Blower Discharge)

ROUND DUCT*

ADDITIONAL

1½” FRAMING

MOUNTING

SCREW

Mounting brackets

factory-shipped in

position for ½” 

ceiling material.

CEILING JOIST

(16” centers shown)

Blower factory-shipped

in straight through

discharge position.

2 X 4 FRAMING

(wide side down)

ROUND DUCT*

CEILING JOIST

(16” centers 

shown)

FINISHED

CEILING

MATERIAL

MOUNTING
BRACKETS
(Attached to

opposite sides

of housing &

upside-down)

BLACK

TO

BLACK

WHITE

TO

WHITE

GROUND TO

WIRING PLATE

TOP / BACK

OF HOUSING

WIRING

PLATE

120 VAC LINE IN

ROOF CAP

ROUND DUCT*

ROUND

ELBOW*

WALL 

CAP

Содержание VCDD0110I

Страница 1: ...Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring or other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 To reduce the risk of fire use only metal ductwork 8 If this unit is to be installed over a tub or shower it must be marked as appropriate for the ap...

Страница 2: ...twork Use duct tape to make ductwork connections secure and air tight Remove shipping ring from blower inlet Remove the shipping ring from the blower inlet before operating the ventilator WIRING Ventilator can be wired from outside of housing Use UL approved connectors to wire per local codes DUCTING Straight Through Blower Discharge ROUND DUCT ADDITIONAL 1 FRAMING MOUNTING SCREW Mounting brackets...

Страница 3: ...e sure blower assembly is completely dry before reinstalling Motor is permanently lubricated Do not oil or disassemble motor Blower and duct connector in straight through discharge position Factory shipped Blower and duct connector in right angle discharge position WIRING OPTIONS Wiring plate mounts to side or top of housing WIRING PLATE POSITION Mounting brackets in factory shipped position Outle...

Страница 4: ... 11 98009399 Inlet Ring 12 99110805 Blower Wheel 13 99080481 Motor VCDD010I 99080482 Motor VCDD015I 99080483 Motor VCDD020I 99080484 Motor VCDD025I 99080485 Motor VCDD030I 14 99260558 Lock Nut 8 32 4 req 15 99250959 Washer 4 req 16 99100491 Grommet 4 req Blower Assembly Complete Includes Key Nos 5 10 16 97014800 VCDD010I 97014801 VCDD015I 97014802 VCDD020I 97014803 VCDD025I 97014804 VCDD030I 17 99...

Отзывы: