![Express ENCORE EXE3 Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/express/encore-exe3/encore-exe3_owners-manual_2452449005.webp)
Express
®
EnCore™
Owner’s Manual
I.B. 1660
4
Output Power Letter Codes
The following table describes the letter codes to be used in charger part numbers to indicate
the Output Power of the charger.
Letter
Code
Output Power
(kW)
Number
Modules
Module Power
(kW)
G
3.5
1
3.5
H
7.0
2
3.5
I
10.5
3
3.5
J
14.0
4
3.5
K
17.5
5
3.5
L
21.0
6
3.5
M
24.5
7
3.5
N
28.0
8
3.5
Cabinet Size/Gauge Letter Codes
The following table describes the letter codes to be used in charger part numbers to indicate
the number of slots and size of the DC cables.
Letter
Code
Module
Positions
Standard Cable
Gauge
Comments
N
4
3/0
Four slot, 3.5 kW cabinet
P
6
3/0
Six slot, 3.5 kW cabinet
R
8
3/0
Eight slot, 3.5 kW cabinet
DC Voltage Number Codes
The following table describes the number codes to be used in charger part numbers to
indicate the DC output voltage(s) of the charger.
Number
Code
Output
Voltage(s)
4
24/36/48
5
72/80